Maintenance
This section describes product maintenance.
7.1
Maintenance table
The component's mechanism and/or electronics do not require any maintenance.
NOTICE
Mechatronic cylinders can get jammed.
Do not lubricate the mechatronic cylinders.
Components
Measures
Interval
All types of
mechatronic cylin-
der
Function check as specified in the in-
structions for the components
12 months
Replacing the batteries
24 months
Clock (compon-
ents)
Checking and setting the time with the
programmer 1460
12 months
7.2
Cleaning
Only disinfection agents that are explicitly formulated for cleaning delicate metal
surfaces and plastics may be used. The use of unsuitable cleaning agents or methods
can damage the components' surface.
1. Use a soft, damp cloth to clean the surface.
7.3
Function check
ü
Mechatronic cylinder installed
ü
E-module installed and connected to cylinder
ü
Battery inserted in e-module
1.
2.
the authorised user key into the cylinder.
ð
The acoustic signal denotes the access authorisation.
ð
The lock can be actuated.
3. Insert an unauthorised user key into the cylinder.
ð
An acoustic signal sounds 4 x briefly.
ð
The lock cannot be actuated.