background image

42  

k1evo805en-2012-09 

Kaba digital cylinder

Maintenance and fault rectification

User manual

8.1.6 Emergency opening 

If all alarm messages have been ignored, up to the point where the batteries are completely 
discharged, it will no longer be possible to operate the digital cylinders. 

Emergency opening with a new battery 

In this case, insert a new battery. 

See page 28

.  

Emergency opening with programmer

Emergency opening can also be executed using the programmer. 

For access authorisations with time settings and CardLink, always set the clock 
precisely after emergency opening.  

The separate user manual for the programmer contains a detailed description of 
emergency opening. 

1. Remove outer door knob. 

2. Connect the programming 

cable.

3. Open using the programmer.  

4. Set the clock using the 

programmer.

Summary of Contents for 1435MID

Page 1: ...EN Kaba digital cylinder User manual Doc no k1evo805en 2012 09...

Page 2: ...2 M hleb hlstrasse 23 Tiverton Industrial Estate 3130 Herzogenburg 8620 Wetzikon Tiverton Devon Austria Switzerland EX16 655 www kaba co uk www kaba com www kaba com This documentation may not be rep...

Page 3: ...7 2 2 2 ESD protective measures for installation 8 2 2 3 Areas of use 8 2 2 4 Disposal of packaging 9 2 2 5 Disposing of digital cylinders and batteries 9 3 Product description 10 3 1 Scope of supply...

Page 4: ...7 2 3 Restore factory settings 36 7 3 Programming with programmer and software 37 7 3 1 Programming with the programmer 37 8 Maintenance and fault rectification 39 8 1 Servicing 39 8 1 1 Maintenance i...

Page 5: ...em and does not replace product training 1 3 Content and purpose The content of the user manual is limited to installation programming operation and maintenance of the Kaba digital cylinder 1 4 Supple...

Page 6: ...are explained in the glossary on page 45 In order to simplify the user manual for the reader the mechatronic locking cylinder Kaba digital cylinder is referred to as digital cylinder for short and th...

Page 7: ...ct 2 2 1 Handling of lithium batteries WARNING Risk of personal injury or death Incorrectly used or installed digital cylinders prevent emergency exit closures or panic closures from opening Risk of e...

Page 8: ...lock manufacturers EC conformity certificates If the digital cylinder is not listed on the certificates from the lock manufacturer or the lock does not comply with these standards an EC conformity ins...

Page 9: ...aste Electrical devices must be disposed of in line with the waste disposal and environmental guidelines applicable in the relevant country Disposal in Germany Kaba devices are registered as B2B in th...

Page 10: ...1 quick start guide 3 2 Additional accessories Kaba service tool item number 1430 25 Hexagonal screw hex 1 5 mm item number 1430 55 Programmer 1460 Kaba media Kaba evolo Manager software 3 3 Types MI...

Page 11: ...tandard internal knob 35 mm Outward opening door Dual internal knob 25 mm Outward opening door Small internal knob Power supply Battery 3 V CR2 Lithium type Operating environments Protection class Ext...

Page 12: ...thout reset can be seen from the diagrams No modifications of any type are permitted with the exception of those detailed in this user manual a upper authorised rest area b lower authorised rest area...

Page 13: ...le cylinder Dimension drawing 1435 Standard 17 mm profile cylinder Description for Standard version Item Item 1 External knob 8 Securing shackle 2 Cover with illumination 9 LA length on outer side 3 E...

Page 14: ...nob 17 mm profile cylinder Dimension drawing 1439 Dual 17 mm profile cylinder With the cylinder lengths leave a gap of at least 1 mm between the door furniture and the door knob so that the service to...

Page 15: ...e doors The user media are electronic keys Each digital cylinder recognises its own user media and only grants access authorisation to these media All user media must be programmed with an access auth...

Page 16: ...hile user media are held up in front of the digital cylinder this cylinder emits various acoustic and optical signals The acoustic and optical signals can be activated or deactivated using the program...

Page 17: ...se the mechatronics unit engages When the battery is almost empty the 2 x long acoustic signals and the 4 second pause remind the user to insert a new battery so that the doors can continue to be open...

Page 18: ...end locking stud size PZ 2 5 2 Installation variants With installation variant A remove the inner door knob and push the cylinder through the door furniture and the lock from the outer side of the doo...

Page 19: ...the lock and door furniture manufacturers are observed Check the dimensions 1 Check the door thickness with the door furniture LA and the cylinder length 2 Check the profile cutout and the backset D W...

Page 20: ...tallation A from the outer side of the door 1 Using the hexagonal key loosen the screw from the inner door knob 2 Remove the inner door knob 3 Align the cam flush with the cylinder housing 4 From the...

Page 21: ...stud 9 Check that the door knobs function correctly Both door knobs can be turned without touching the door furniture 10 Check the backset The door knobs must not knock against the door frame 11 Inser...

Page 22: ...ock by turning the door knob 14 Turn the inside knob of the digital cylinder clockwise until just before the upper rest area 11 o clock position 15 Hold this position in doing so it should be possible...

Page 23: ...rom electrostatic discharge Installation B from the inner side of the door 1 Position the service tool on the inner side of the outer door knob 2 Turn the service tool clockwise and unlock the outer d...

Page 24: ...ual 8 Remove the door furniture without profile cutout 9 Align the cam flush with the cylinder housing 10 Push the cylinder housing through the lock from the inner side of the door 11 Position the for...

Page 25: ...e screw using the hexagonal key 15 Check the position of the O ring Push the electronical module onto the cylinder housing ensuring that the O ring is not damaged in the process 16 Push the securing s...

Page 26: ...outer door knob over the electronical module 19 Attach the service tool to the outer door knob 20 Rotate the service tool anticlockwise and lock it The outer door knob and the cylinder housing are no...

Page 27: ...position in doing so it should be possible to feel the reset force 27 Press down the lever handle which should open the latch the bar and the door 28 Let go of the inside door knob the inside knob sh...

Page 28: ...s prevents lock out in the case of self locking locks ATTENTION Danger of damage to electronic components from electrostatic discharge Disassemble the outer door knob 1 Position the service tool on th...

Page 29: ...has been successful Assemble the outer door knob The outer door knob can only be attached in one position The Kaba logo and the upper surface of the battery compartment must be on the same side 6 Push...

Page 30: ...ers can be individually programmed with the media on site in a manual process using the master media It is not possible to program time functions with this type of programming 7 1 1 Master media With...

Page 31: ...A structure With each B master separate access authorisations can be granted to user media A user medium can be programmed with various B masters but not with the same digital cylinder Up to 4000 user...

Page 32: ...ion Confirmation Launch programming mode 1 Hold the A master medium in front of the outer door knob for approx 1 s 1 x short Program B master 2 Hold the B master medium in front of the outer door knob...

Page 33: ...short Programming user media 2 Hold user medium in front of outer door knob for approx 1 s 1 x short 3 Hold further user media in front of outer door knob for approx 1 s 1 x short End of programming m...

Page 34: ...ter medium in front of the outer door knob for approx 1 s 1 x short Deleting user media 2 Hold user medium in front of outer door knob for approx 3 s 2 x short End of programming mode 3 Hold the B mas...

Page 35: ...ter medium in front of the outer door knob for approx 1 s 1 x short Delete B master 2 Hold the B master medium in front of the outer door knob for approx 3 s 2 x short End of programming mode 3 Hold t...

Page 36: ...rt A master 1 Hold the A master medium in front of the outer door knob for approx 10 s 2 x short 10 s 1 Beep Beep 10 s 1 Beep Beep All master media and user media will be deleted The traceback will be...

Page 37: ...o main functions that can be executed on the digital cylinders using the programmer are write export and read import data These functions always require a valid master Data can be exported and importe...

Page 38: ...aceback Configuration The existing configuration data for the digital cylinders stored on the programmer will be overwritten following confirmation 1 Press Import menu key 2 Log in to the digital cyli...

Page 39: ...tal cylinder Check on the components and function 1 month Repair of the cam s spring mechanism required 10 years All types Kaba digital cylinder Function check as specified in user manual for the comp...

Page 40: ...y turning the door knob 2 Turn the inside knob of the digital cylinder clockwise until just before the upper rest area 11 o clock position 3 Hold this position in doing so it should be possible to fee...

Page 41: ...w battery ready See page 28 8 1 4 Setting the clock A programming device is necessary to set and check the clock in the digital cylinders Always check the time following a change of batteries or at le...

Page 42: ...ing with a new battery In this case insert a new battery See page 28 Emergency opening with programmer Emergency opening can also be executed using the programmer For access authorisations with time s...

Page 43: ...dium The programmer can also be used to implement an INI reset The valid master medium is also required for this variant The separate user manual for the programmer contains a detailed description of...

Page 44: ...nal Optical signal Possible causes Measures No optical or acoustic signals mechatronics is functioning correctly Signals were deactivated with the programmer Check configuration with the programmer De...

Page 45: ...chatronic components include digital cylinders for example Opening times The opening times for a digital cylinder can be selected in the programmer The time opening time for which a digital cylinder s...

Page 46: ...46 k1evo805en 2012 09 Kaba digital cylinder User manual Notes...

Page 47: ...User manual Glossary Kaba digital cylinder k1evo805en 2012 09 47...

Reviews: