(P/N) 760.128 Rev G 12/13 • © copyright 2004-2013
Kaba Mas LLC
Page 2 of 2
LOCK OPERATIONS
CHANGE COMBINATION Manager and User
NOTE: Each combination must be changed independently at the Lock. New combination will not be accepted if it varies from the current
combination by only one digit (+/-). When selecting a combination, do not use a birthday or other predictable information that could give
correlation between the user and the combination.
CAUTION: Always perform this operation with the door open, and test the opening of the Lock with the new combination several times before
closing the door.
1. Enter zero [0] six times.
Ex.
(0-0-0-0-0-0)
2. Enter an existing combination.
Ex.
(1-2-3-4-5-6)
3. Enter the NEW combination.
Ex.
(6-5-4-3-2-1)
4. Re-enter the NEW combination to confirm
Ex.
(6-5-4-3-2-1)
The NEW combination is now active.
5. Test lock operation several times before closing the door.
MANAGER COMMANDS
COMMAND 1
Activate User
1. Enter Manager combination and
hold down last digit of combination until Lock double signals and the LED stays on.
2.
PRESS 1.
3. Enter the NEW User combination.
4. Re-enter the NEW User combination to confirm. User combination is now active.
Reinstate User
1. Enter Manager combination and
hold down last digit of combination until Lock double signals and the LED stays on.
2.
PRESS 1.
3. Enter User number (1- 9). User is reinstated.
COMMAND 2
Disable User
1. Enter Manager combination and
hold down last digit of combination until Lock double signals and the LED stays on.
2.
PRESS 2. User is temporarily disabled. The User combination is saved and will be valid once reinstated.
COMMAND 3
Delete User
1. Enter Manager combination and
hold down last digit of combination until Lock double signals and the LED stays on.
2. PRESS 3. User is deleted.
Super Master Reset (SMR)
SMR will reset the lock back to factory state, but SM code remains unchanged. The default code of 5-5-5-5-5-5-5-5 must be changed
before the Manager default code is changed or the function will be permanently lost.
Process is as follows:
Action - Press and hold [0] key for 3 seconds
Result – Lock beeps twice and the LED is ON, until the process is complete
Action – default code is entered 5-5-5-5-5-5-5-5 (last digit must be held for 3 seconds)
Result – Command Menu access is granted.
SMR has only 2 Command options available.
If press [0] = change code, (1 time use)
NOTE: once the default code is changed to a new code the code can never be changed. A reset box must be used to reset.
If press (8) = Reset the lock.
BATTERY MAINTENANCE & REPLACEMENT
• It is recommended that batteries be replaced at least once a year.
• The use of a high quality, name brand alkaline battery (Energizer® or Duracell®) is recommended.
• If the battery is depleted, follow the battery changing instructions for the Entry Device you are using. Battery changing instructions can be
found in either the
Electronic Entry Device Installation Instructions (762.128) or in the respective Entry Device User Instructions for the
Entry in operation.
The latest versions of LA GARD documentation are available for download at www.kaba-mas.com.
NOTE: The Input Unit 3190, audit features, the software features associated with peripheral devices and systems, the silent alarm feature, and
other additional features have not been evaluated by UL.