12
Previous to a lock being activated in any mode, the prompts ##, #4, and #70, 72, 76,
78 and 79 will display the error. #72 only applies to Gen2 locks activated with a USB
Key Box.
After a particular mode is shelved, the ## and #4 prompts will still display “” to give
information about a mode the last time it was active, though the remaining #7x
prompts mentioned will start showing the error again.
Cencon Lock LCD Terminology
The irst step in learning the operation of the Cencon Lock is understanding what is
shown on the display.
Note:
The Cencon LCD uses a 7-segment font, displaying up to 3 characters
at a time. Some displays will be a mixture of numbers and both capital and
lower case letters.
Lock Displays/Prompts Used on Swing Bolt Gen2
1. =
DL
Dial briskly in either direction to power the lock.
2. =
EC
Enter Combination
3. =
OPr
Turn bolt handle to open the container door.
4. =
CLb
(
Change Key
Function Activated)
5. =
E
nter
C
urrent combination (Shelved mode/Factory)
6. =
E
nter
N
ew combination (Shelved mode/Factory mode)
7. =
C
onirm
N
ew
c
ombination (Shelved mode/Factory mode)
8. = Lightning Bolt (Error); usually wrong combination
9. =
L
ock
O
ut condition due to 5 lightning bolts
10. =
I
nsert
P
ersonal
I
dentiier (key) 1
11. =
C
lose Seal number (where 0 is a number)
12. =
EOP
(
E
nd
O
f
P
rocess)
13. = “
?
” displayed when the command key (#) is pressed
14. = (##) -
S
eal
C
ount** for an active mode by user key
15. = (##) -
S
eal count** for a Shelved mode by user key
16. = (#1) -
L
ock irmware code
L
evel
17. = (#1) -
H
ardware
L
evel of lock back cover
18. = (#2) -
S
erial
N
umber of lock back cover
19. = (#3) - Total (
A
ll modes) opening Count
**Seal count, Opening Count, and Audit Count are terms used
interchangeably throughout the documentation.
21. = Indicates
G
en
2
lock during power-up
22. =
R
emote
L
ock
O
ut signal; keypad entry is prevented
23. = (#71) -
UTC
/GMT date and time of lock
24. = (#71) - Date, starting with
Y
ear, then Month, then Day
25. = (#71) - Time, starting with
H
our, then Minute, then Second
26. = (#73) -
C
encon
i
Button (key) Model Number
27. = (#73) -
C
encon iButton (key) Serial Number
28. = (#74) -
OP
ened
D
oor
29. = (#74) -
CL
osed
D
oor
30. = (#74) -
N
o door
C
ontact
C
onnection
31. = (#77) - UTC/GMT date and time on
P
ersonal
I
dentiier Key’s
C
lock
For a full listing of Lock LCD Terminology, including displays only shown while the