![K2L OptoLyzer MOCCA compact FD User Manual Download Page 24](http://html1.mh-extra.com/html/k2l/optolyzer-mocca-compact-fd/optolyzer-mocca-compact-fd_user-manual_648798024.webp)
OptoLyzer MOCCA Devices
DS60001526B
24
© 2017 - 2018 K2L GmbH & Co. KG
K2L USER MANUAL
6.3 LIN / CAN FD 7/8
Connector type (see
The provided GND pin must not be used unless there is no other GND connection. This pin must not
be used for supply purpose.
6.4 Synchronization and Power
Connector type: Binder sensor connector series 768, 3 pole, ordering number: 09 3419 82 03
Suitable female connector: Binder M8 IP40 series 768, 3 pole, ordering number: 99 3400 100 03
There are two connectors for synchronization and power.
shows the pins as they are visible
on the rear panel for these connectors. For more details about synchronization and power refer to
Section 2.1, "Supply and Synchronization," on page 10
Figure 6.2 Pin Assignment of the Sync and Power Connector
Table 6.4 Pin Assignment of Connector LIN / CAN 7/8
PIN NO.
SIGNAL
DESCRIPTION
1
Not connected
2
CAN FD 7-Low
Low-level CAN FD 7 bus line
3
GND
Signal ground
4
CAN FD 8-Low
Low-level CAN FD 8 bus line
5
LIN 1
1
st
LIN channel
6
LIN 2
2
nd
LIN channel
7
CAN FD 7-High
High-level CAN FD 7 bus line
8
Not connected
9
CAN FD 8-High
High-level CAN FD 8 bus line