4 For Professional Technical Support call 1-844-242-2475
INSTALLATION
(SEE FIGURES 1 AND 2)
WARNING:
Electric Shock Hazard. Plug pump into a properly grounded, GFCI protected outlet. Do NOT plug in the
pump until after it is completely installed. Do not remove or modify the grounding pins on the plugs.
NOTE:
5 inches space is needed from sink bottom to inlet for proper operation, refer to figure 2.
Fittings Supplied: Qty.
A Sink Drain Screen 1
B 1-
1/4” NPT x 1-1/4” Slip Check Valve 1
C 1-
1/4” NPT Ball Valve 1
Purchase Separately: Qty.
1 1-
1/2” NPT x 1-1/2” Slip Female Adapter 1
2 1-
1/2” Schedule 40 PVC Pipe, to fit 1
3 1-
1/2” NPT x 1-1/2” Slip Male Adapter 1
4 1-
1/4” NPT Galvanized Nipple (to fit) 1
5 1-
1/4” NPT Galvanized Union 1
6 1-1/4
” NPT x 1-1/4” Male Adapter 2
7 1-
1/4” Schedule 40 PVC Pipe, to fit 2
8 1-
1/4” Socket to Socket 90° Elbow 1
9 1-
1/4” Schedule 40 PVC Pipe to Drain As Needed
PVC Pipe Cement As Needed
PTFE pipe thread sealant tape As Needed
1-
1/2” PVC Solvent Union – optional As Needed
NOTE:
Be careful to avoid cross-threading; Use only a
plastic-compatible pipe-threading compound or teflon tape
when connecting threaded fittings to plastic adapters.
Figure 1: Typical method of mounting the pump
Mount the pump
NOTE:
DO NOT use plumber’s pipe threading compound (“pipe dope”) on plastic pipe; it can damage the plastic,
causing leaks and piping failure and void the warranty.
1.
Place the sink in its final location.
2.
Remove any existing drain fittings back to the tail piece. Make sure the existing tail piece does not leak.
NOTE
: If the sink-drain tail piece is not 1-1/2 in. NPT, you will have to adapt it (bushings, reducers, etc.). In this case,
wrap all joints with PTFE pipe thread sealant tape before making connections.
3.
Glue the 1-1/2 in. PVC pipe into the female adapter (Part No.1).
WARNING:
Fire and explosion hazard. Be sure to follow the cement manufacturer’s instructions when using PVC
cement. Do not use near fire or open flame.
4.
Wrap the threads of the tail piece with 1 to 1-1/2 turns of PTFE pipe thread sealant tape. Thread the 1-1/2 in. NPT
female adapter (Part No.1) onto the sink-drain tail piece. Thread it hand tight plus 1/2 turn with a pipe wrench or slip
joint pliers. DO NOT overtighten.