1.8 I/O Menu
Page 50
Docu-No.: 0590020601-EN Rev. 1.6.0
1.8.2
Digital output sub-menu
It is not allowed to change Digital output function, polarity and map if
the feeder is running.
Parameter
Definition
DIG OUT
Digital Output
Selection of the desired bit output of the KCM for programming.
Select CPU_Out1 to CPU_Out4, MDU Relay 1, MDU Relay 2, MDU
Relay 3, Spare, Ext_Out1 to Ext_Out8.
Input Range: See list
Note:
For Ext Out function to work, Modbus I-O must be configured first
and the external I-O module (e.g.WAGO) connected via K-Port 2.
FUNCTION
Digital Output Function
Input function of the selected output no. [1-16]
Selections:
None, Run, Any Alarm, Alarm Relay, ALS Out, Drive Ena, Grav
Mode, PSR_MAP^, ASR_MAP^, Totalizer_Pulse, Refill, Refill
Expired, Loader, Blow_Off, HiLo_Gear.
Input Range: See list
Default: CPU_Out_1 = Feeder Run, CPU_Out_2 = Refill,
CPU_Out_3 = Hard Alarm, CPU_Out_4 = Drive Enable,
MDU_Relay1 = None, MDU_Relay2 = Refill, MDU_Relay3 = None
STATE
Digital Output State
Displaying the actual status of the selected digital output.
Input range: Display only (Off or 0 = not active, On or 1 = active)
POLARITY
Polarity
The selected digital output changes the function from e.g. NO to NC.
Selections are:
Input range: Normal or Inverse
Default: Normal
EXT TOT PULS
External Totalizer Pulse
Input of the resolution of an external Totalizer
Input range: 0* to 999999
Default: 0 kg/pulse
The maximum pulse rate is 3 pulses/second.
The calculation of the increment is as follows:
Ext Tot Increment(min) = Massflow[kg/hr]/1000
DIGOUT MAP
Digital Output Map
If at the variable <FUNCTION> the selection PSR-MAP or ASR MAP
was made, it is possible to program any output function listed in the
table in the appendix. See sections
and