2 a) Electrical: Electrical work must be performed by a qualified Electrician
and comply with the Canadian Electrical Code or the American National
Standard Electrical Code lnforce.
Table 02.
The wire sizes to be used are as follows:
For installation see Wiring Schematic figure 03.
FIGURE 03.
Wiring Schematic
In Accordance with The Electrical Code in effect
b)
A green coloured terminal (or a wire connector marked “C”,“GP”. “Ground”
or “Grounding”) is provided within the control box. To reduce the risk
of electric shock, connect this terminal or connector to the grounding
terminal of the electric service or supply panel with a continuous green
insulated copper wire equivalent in size to the circuit conductors
4
Model
Amps
Fuse
(240V G.F.L. Size)
Wire Size
(90’ Copper Only)
Collector
Ground Wire
(Copper Only)
K-5 & KS-5
21A
30A
10
10
K-10 & KS-10
42A
60A
6
6
K-15
63A
80/100A
Use Supply conductor
suitable for 75º C
Use Supply conductor
suitable for 75ºC
3
MECHANICAL INSTALLATION DIAGRAM
SHOWING BY PASS
Caution:
i) Do not store chlorine near or in the same room as heater.
ii) Valves must not be installed in the piping on the
outlet of heater to the pool.
iii) Use PVC cement for connecting leakage current collectors
into tank body and use teflon tape as sealer in the threads
for drain plug.
d)
Water Flow
The water flow in GPM should not exceed the following limits:
Table 01
Important:
Systems with higher GPM ratings will require a bypass around Heater.
This would be necessary if a high velocity pump is employed in the system.
Recommended:
Add water softener for longer heater life.
Heater
GPM
K-5 / KS-5
08 (Max)
K-10 / KS-10
10
K-15
10