background image

SPRINKLER INSTALLATION

1

INSTALL AND BURY

Do not use pipe dope. Thread the sprinkler on the pipe. Bury the
sprinkler flush to grade. NOTE: Gear driven sprinklers and pop-up
sprays should not be installed on the same watering zone.

2

INSPECTING THE  FILTER

Unscrew the top and lift the complete sprinkler assembly out of the
housing can. The filter is located on the bottom of the sprinkler
assembly and can easily be pulled out, cleaned and re-installed.

3

WINTERIZATION TIPS

When using an air compressor to remove water from the system
please note the  following:

1) Do not exceed 30 PSI.

2) Always introduce air into the system gradually to avoid air

pressure surges. Sudden release of compressed air into the
sprinkler can cause damage.

3) Each zone should run no longer than 1 minute on air. Sprinklers

turn 10 to 12 times faster on air than on water. Over spinning
rotors on air can cause damage to the internal components.

K2 SMART

SET

GEAR DRIVEN SPRINKLER SETTING INSTRUCTIONS

STANDARD NOZZLE PERFORMANCE

METRIC

Pressure   Radius         Flow

KPa

Bars 

Meters        L/M       M

3

/H

206

2.04

11.6

9.46

.57

275

2.72

11.9

10.60

.64

345

3.40

12.2

12.11

.73

413

4.08

12.5

13.25

.79

206

2.0

8.5

1.89

.11

275

3.0

8.8

2.27

.14

345

3.5

8.8

2.65

.16

413

4.0

9.1

3.03

.18

206

2.0

8.8

2.65

.16

275

3.0

9.1

3.03

.18

345

3.5

9.4

3.41

.20

413

4.0

9.8

3.79

.23

206

2.0

9.8

4.92

.14

275

3.0

10.1

5.68

.18

345

3.5

10.4

6.05

.20

413

4.0

10.7

6.81

.23

206

2.0

11.3

9.08

.54

275

3.0

12.2

9.46

.56

345

3.5

12.8

11.35

.68

413

4.0

13.1

12.49

.75

206

2.0

11.6

13.63

.75

275

3.0

11.9

15.89

.95

345

3.5

12.5

17.41

1.04

413

4.0

12.8

18.92

1.13

206

2.0

13.1

16.65

.99

275

3.0

13.4

19.30

1.15

345

3.5

14.0

21.19

1.27

413

4.0

14.9

22.33

1.33

206

3.0

13.7

22.33

1.33

275

3.5

14.0

22.71

1.36

345

4.0

14.6

23.85

1.43

413

5.0

14.9

25.35

1.52

206

3.0

12.8

30.28

1.81

275

3.5

13.7

32.12

1.92

345

4.0

14.8

35.95

2.15

413

5.0

15.3

37.85

2.27

U.S.

Nozzle  Pressure  Radius    Flow

PSI

Ft.        GPM 

#2.5

30

38'

2.5

Factory

40

39'

2.8

Installed

50

40'

3.2

Nozzle

60

41'

3.6

#0.5

30

28'

0.5

40

29'

0.6

50

29'

0.7

60

30'

0.8

#0.75

30

29'

0.7

40

30'

0.8

50

31'

0.9

60

32'

1.0

#1

30

32'

1.3

40

33'

1.5

50

34'

1.6

60

35'

1.8

#2

30

37'

2.4

40

40'

2.5

50

42'

3.0

60

43'

3.3

#3

30

38'

3.6

40

39'

4.2

50

41'

4.6

60

42'

5.0

#4

30

43'

4.4

40

44'

5.1

50

46'

5.6

60

49'

5.9

#6

40

45'

5.9

50

46'

6.0

60

48'

6.3

70

49'

6.7

#8

40

42'

8.0

50

45'

8.5

60

49'

9.5

70

50'

10.0

LOW ANGLE NOZZLE PERFORMANCE

METRIC

Pressure   Radius         Flow

KPa

Bars 

Meters         L/M       M

3

/H

207

2.04

6.71

4.54

.34

275

2.72

7.32

5.43

.39

344

3.40

7.92

6.80

.41

413

4.08

8.53

7.56

.46

207

2.04

8.84

11.34

.68

275

2.72

9.75

11.72

.71

344

3.40

10.67

13.23

.80

413

4.08

11.58

14.36

.87

207

2.04

9.45

12.85

.78

275

2.72

10.36

14.74

.89

344

3.40

11.28

16.63 1.00

413

4.08

11.58

17.77 1.07

275

2.72

11.58

24.57 1.68

344

3.40

12.19

27.59 1.76

413

4.08

12.80

30.24 1.82

482

4.76

13.41

32.51 1.96

U.S.

Nozzle  Pressure  Radius    Flow

PSI

Ft.        GPM 

#1

30

22'

1.2

40

24'

1.7

50

26'

1.8

60

28'

2.0

#3

30

29'

3.0

40

32'

3.1

50

35'

3.5

60

37'

3.8

#4

30

31'

3.4

40

34'

3.9

50

37'

4.4

60

38'

4.7

#6

40

38'

6.5

50

40'

7.3

60

42'

8.0

70

44'

8.6

Data represents test results in zero wind for K2 SmartSet. Adjust for local
conditions. Radius may be reduced with nozzle retention screw.

Reviews: