KMT12/KMT18
REV. A
12
For best performance, voltage drops should not exceed 10% at 115V or 5% at 230V. The minimum electrical
service amperage required by a K-array loudspeakers system is the sum of their maximum continuous RMS
current. We recommend allowing an additional 30% above the minimum amperage to prevent peak voltage
drops at the service entry.
410VA(>10 sec) - 2200VA (<1 sec)
KMT12/KMT18 max continuous apparent power (VA)
8.4 REAR PANEL
1
2
3
4
5
12
13
14
15
16
17
18
19
19
20
6
7
10
11
9
8