background image

KMT18P

Ver. 1.3

11

11. CERTIfICATIoN

K-array

s.r.l. a socio unico società soggetta alla attività di direzione e coordinamento di HP Sound Equipment spa

P. IVA / VAT / CF

06206990480

- R.E.A. 609589   Cap. soc. i.v. € 100.000,00

Sede legale: via Paolina Romagnoli   17 50038  Scarperia e San Piero - Firenze - ITALY tel +39 055 8487222    fax +39 055 8487238

[email protected] www.k-array.com

DECLARATION OF CONFORMITY

Manufacturer/Importer: K-array

s.u.r.l.

Brand

:

K-ARRAY

Address:

via Paolina Romagnoli 17 50038 Scarperia e S. Piero Firenze ITALY

Date of Issue:

05 / 05 / 2015

Model Code:

KMT18P, KMT18PX

Declaration:

Complies with safety essential requirements of Council Directive

2004/108/EC on the approximation of the Laws of the Member States relating to 

electromagnetic compatibility.

2006/95/EC on the harmonisation of the laws of member state relating equipment 

designed for the use within certain voltage limits

This declaration applies to all specimens manufactured in accordance with the attached 

manufacturing drawings which form part of this declaration. Assessment of compliance 

of the product with the requirements relating to electromagnetic compatibility and low 

voltage directive was based on the following standards:

EMC:

EN 55103-1:2009

EN 55103-2:2009

EN 61000-3-2:2006+A1+A2

EN 61000-3-3:2008

Safety:

EN 60065:2002+A1+A11+A2+A12

Marking:

Applying Year:

2015

Applied by:

K-array

s.u.r.l.

Via Paolina Romagnoli 17

50038 Scarperia e S. Piero

Firenze Italy

Tel. +39 055 8487222

Fax +39 055 8487238

Signed by:

Franco Spataro

Technical Manager

Summary of Contents for KMT18P

Page 1: ...KMT18P Ver 1 3 KMT18P USER GUIDE English ...

Page 2: ...ABLE of CONTENTS SYMBOLS 3 1 INTRODUCTION 4 2 KEY features 4 3 APPLICATIONS 4 4 SAFETY information 5 5 UNPACKING 6 6 physical 6 7 wiring 7 8 HANGING POINTS 8 9 SERVICE 9 10 TECHNICAL specifications 10 11 certification 11 ...

Page 3: ...ration please observe the respective country specific regulations WEEE Please dispose of this product at the end of its operational lifetime by bringing it to your local collection point or recycling center for such equipment This device complies with Restriction of Hazardous Substances Directive SYMBOLS Warning Dangerous voltages RISK of electric shock Terminals marked with this symbol are HAZARD...

Page 4: ...he cabinet despite its light weight Pocket handles and an M20 thread mount position for attaching mid high speakers makes it convenient to use and ideal for medium throw applications in theaters concert halls and Audio Video installations All KMT components are designed by K array and custom made under K array s quality control system Unique performance to size ratio High power 127 dB continuous 1...

Page 5: ...om small children Do not make repairs yourself Never attempt to disassemble repair or modify the system yourself Disassembling the unit may cause damage that is not covered under the warranty The device contains no user serviceable parts Repairs should only be performed by factory trained service personnel Sound distortion Do not operate speakers for an extended period of time with sound distortio...

Page 6: ...horoughly inspected before leaving the factory Upon arrival carefully inspect the shipping carton then examine and test your new amplifier If you find any damage immediately notify the shipping company Only the consignee may institute a claim procedure regarding the system s electronic equipment Weight 24 6 kg 54 2 lbs 6 physical ...

Page 7: ...designed to pick up audio power signal from pins 1 1 of a NL4 connector 2 and 2 pins just like 1 and 1 are directly wired from one socket to the other so the signal can pass through multiple speaker modules without additional external cabling Rear panel ...

Page 8: ...s apparatus must be securely attached to the floor wall in accordance with the installation instructions Tipping shaking or rocking the machine may cause injury or even death K array is not responsible for any rigging equipment and accessories that are not manufactured by K array It is the user s responsibility to ensure that the Working Load Limit WLL of all the additional rigging hardware access...

Page 9: ... send the unit in for service In this instance you will be provided with an RA Return Authorization number which should be included on all shipping documents and correspondence regarding the repair Shipping charges are the responsibility of the purchaser Any attempt to modify or replace components of the device will invalidate your warranty Service must be performed by an authorized K array servic...

Page 10: ...ions 46 5 cm x 46 5 cm x 59 2 cm 12 8 x 12 9 x 17 0 Weight 24 6 kg 54 2 lbs Notes for data 1 Maximum RMS applicable power for a musical signal The reference signal is the one proposed by EIAJ standard 2 With dedicated preset 3 Measured 4 mt then scaled 1 mt 4 Measured with musical signal New materials and design are introduced into existing products without previous notice Present systems may diff...

Page 11: ...on the approximation of the Laws of the Member States relating to electromagnetic compatibility 2006 95 EC on the harmonisation of the laws of member state relating equipment designed for the use within certain voltage limits This declaration applies to all specimens manufactured in accordance with the attached manufacturing drawings which form part of this declaration Assessment of compliance of ...