PXIe-

6

3988

PXI Express Embedded Controller

 

User’s Manual

Manual Rev.: 

1.0

Revision Date: 

July 04, 2021

Part No: 

50M-00028-1000

Summary of Contents for PXIe-63988

Page 1: ...PXIe 63988 PXI Express Embedded Controller User s Manual Manual Rev 1 0 Revision Date July 04 2021 Part No 50M 00028 1000...

Page 2: ...ii Revision History Revision History Revision Release Date Description of Change s 1 0 2021 07 04 Initial release...

Page 3: ...r inability to use the product or documentation even if advised of the possibility of such damages JYTEK is committed to fulfill its social responsi bility to global environmental preservation through...

Page 4: ...o to www P65Warnings ca gov Trademarks Product names mentioned herein are used for identification pur poses only and may be trademarks and or registered trademarks of their respective companies Conven...

Page 5: ...4 LED Indicators 11 1 3 5 USB 2 0 Ports 12 1 3 6 Gigabit Ethernet Ports 13 1 3 7 USB 3 0 Ports 14 1 3 8 COM Port 14 1 3 9 Onboard Connections and Settings 15 2 Getting Started 17 2 1 Package Contents...

Page 6: ...Revision 40 B Appendix BIOS Setup 41 B 1 Entering the BIOS 41 B 2 Navigation 42 B 3 Menu Structure 43 B 4 Main 44 B 4 1 BIOS Information 44 B 4 2 System Information 44 B 4 3 System Date and Time 45 B...

Page 7: ...guration 55 B 6 Chipset 56 B 6 1 System Agent SA Configuration 56 B 6 2 PCH IO Configuration 57 B 7 Security 59 B 7 1 Secure Boot 59 B 8 Boot 60 B 8 1 CSM 61 B 8 2 UEFI Hard Disk Drive BBS Priorities...

Page 8: ...viii This page intentionally left blank...

Page 9: ...agram 3 Figure 1 2 Front Panel 7 Figure 1 3 PXI Trigger SMB Jack 8 Figure 1 4 DisplayPort Connector 9 Figure 1 5 GPIB Connector 10 Figure 1 6 LED Indicators 11 Figure 1 7 COM Port 14 Figure 1 8 Onboar...

Page 10: ...x List of Figures This page intentionally left blank...

Page 11: ...tion 10 Table 1 4 LED Indicator Legend 11 Table 1 5 USB 2 0 Port Pin Assignment 12 Table 1 6 Ethernet Port Pin Assignments 13 Table 1 7 Ethernet Status LED Descriptions 13 Table 1 8 D sub COM Port Sig...

Page 12: ...xii List of Tables This page intentionally left blank...

Page 13: ...XI Express based testing systems typically make up a PXI Express platform and diversified standalone instruments for com plex testing tasks The PXIe 63988 series provides ample inter faces including t...

Page 14: ...Express Link Capability 4 link Configuration x4 x4 x4 x4 2 link Configuration x16 x8 SATA Storage built in 2 5 500 GB or 240 GB SATA solid state hard drive Supports 2 5 HDD or SSD SATA 6 0 Gb s Suppo...

Page 15: ...Port Connector RS 232 422 485 Intel Xeon E Processor formerly Coffee Lake Intel CM246 Chipset GPIB Controller GbE Controller I219 GbE Controller I210 LCP COM Port Programmable MUX SMBus Controller DP...

Page 16: ...through two RJ 45 connectors with speed link active LED on the faceplate with both supporting Wake on LAN USB Four USB 2 0 and two USB 3 0 ports on the faceplate GPIB Onboard IEEE488 GPIB controller t...

Page 17: ...n Functional shock 30 G half sine 11 ms pulse duration Random vibration Operating 5 to 500 Hz 0 21 Grms 3 axes Non operating 5 to 500 Hz 2 46 Grms 3 axes Condition Range Operating temperature with SSD...

Page 18: ...2013 Table 2 Industrial FCC 47 CFR Part 15 Subpart B Class B ICES 003 Issue 7 2020 AS NZS CISPR 11 Group 1 Class A emissions The PXIe 63988 meets the essential requirements of applicable European Dir...

Page 19: ...Figure 1 2 Front Panel Table 1 1 Front Panel Legend A Reset Button F GPIB Connector Micro D Sub 25P B 2X DisplayPort G 2X Gigabit Ethernet C 2X USB 3 0 H PXI Trigger D 4X Type A USB 2 0 I LED indicato...

Page 20: ...nsitive The PXIe 63988 provides four trigger routing modes from to the PXI trigger connector to synchro nize PXI modules including From a selected trigger bus line to PXI trigger connector From the PX...

Page 21: ...unction is also supported Figure 1 4 DisplayPort Connector Table 1 2 DisplayPort Pin Assignment Pin Signal Pin Signal 1 CN_DDPx0 11 GND 2 GND 12 CN_DDPx3 3 CN_DDPx0 13 CN_DDPx_AUX_SEL 4 CN_DDPx1 14 CN...

Page 22: ...ure 1 5 GPIB Connector Table 1 3 GPIB Pin Description Pin Signal Description Pin Signal Description 1 DIO1 GPIB Data 1 14 DIO5 GPIB Data 5 2 DIO2 GPIB Data 2 15 DIO6 GPIB Data 6 3 DIO3 GPIB Data 3 16...

Page 23: ...cate operational status of the PXIe 63988 as follows Figure 1 6 LED Indicators Table 1 4 LED Indicator Legend LED Color Description PW Green Indicates system power remaining lit when the system boots...

Page 24: ...th hi speed full speed and low speed USB devices Supported boot devices include USB flash drive USB floppy USB CD ROM and others with boot pri ority and device settings configured in BIOS See section...

Page 25: ...follows Table 1 7 Ethernet Status LED Descriptions Pin 1000Base T Signal 100 10Base T Signal 1 MDI0 TX 2 MDI0 TX 3 MDI1 RX 4 MDI2 Reserved 5 MDI2 Reserved 6 MDI1 RX 7 MDI3 Reserved 8 MDI3 Reserved LE...

Page 26: ...BIOS 1 3 8 COM Port A COM port on the front panel with D sub 9P connectors supports RS 232 RS 422 RS 485 by BIOS selection Figure 1 7 COM Port Table 1 8 D sub COM Port Signal Functions NOTE NOTE USB...

Page 27: ...Introduction 15 1 3 9 Onboard Connections and Settings Figure 1 8 Onboard Configuration Table 1 9 Onboard Configuration Legend A Clear CMOS switch B SATA connector C System battery C B A PXIe 63988...

Page 28: ...16 Introduction This page intentionally left blank...

Page 29: ...roller equipped with RAM and HDD or SSD PXIe 63988 63987 63977 63937 Quick Start Guide If any of these items are missing or damaged contact the dealer from whom you purchased the product Save the ship...

Page 30: ...he new operating system 1 Select the appropriate boot device order from the BIOS Boot Setup Menu based on the OS installation media used For example if the OS is distributed on a bootable installation...

Page 31: ...PXIe system controllers are electrostatically sensitive and can be easily damaged by static electricity The equipment must be handled on a grounded anti static mat and operators must wear an anti stat...

Page 32: ...20 Getting Started 2 2 2 Installing the PXIe 63988 1 Remove all screw caps x4...

Page 33: ...Getting Started 21 2 Release the red locking lever 3 Depress the latch 4 Locate the system controller slot of the chassis Slot 1 PXIe 63988...

Page 34: ...63988 into the chas sis as shown 6 Elevate the latch until the PXIe 63988 is fully seated in the chassis backplane The alignment pin on the rear of the latch can be threaded into the best fit alignme...

Page 35: ...0 port with a pre installed 2 5 SATA hard drive or solid state drive Replacing the HDD or SSD is accomplished as follows 1 Locate the five screws attaching the hard drive housing to the PXIe controlle...

Page 36: ...system 2 2 4 Replacing the Battery Backup The PXIe 63988 is provided with a 3 0 V coin cell lithium battery replacement of which is as follows 1 Turn off the PXI chassis 2 Remove the PXIe controller...

Page 37: ...2 2 5 Clearing CMOS In the event of a system malfunction causing the PXIe controller to halt or fail to boot clear the CMOS and restore the controller BIOS to its default settings To clear the CMOS 1...

Page 38: ...controller into the PXI chassis 5 Press Delete or ESC to enter BIOS Setup when the splash logo appears 6 Press F9 to load optimized defaults in BIOS Setup 7 Modify the system date and time 8 Press F1...

Page 39: ...complete installation for the following drivers Chipset Driver Graphics Driver Ethernet LAN Driver PXI Trigger I O Driver Intel ME Driver GPIB Driver Intel RST Driver The following optional utility p...

Page 40: ...28 Driver Installation This page intentionally left blank...

Page 41: ...nded that you use these data types in your application programs The table shows the data type names ranges and cor responding data types in C C Visual Basic and Delphi for ref erence Type Description...

Page 42: ...point 3 402823E38 to 3 402823E38 float Single Single F64 64 bit double precision floating point 1 7976831348 62315E308 to 1 7976831348 62315E309 double Double Double Type Description Range Type C C f...

Page 43: ...of supported cards syntax parameter list and Return Code information A 2 1 TRIG_Init Description Initializes trigger I O function of PXIe 63988 controller TRIG_Init must be called before the invocati...

Page 44: ...I O function of PXIe 63988 controller releas ing resources allocated for the trigger I O function Users must invoke TRIG_Close before exiting the application Syntax C C I16 TRIG_Close Visual Basic TRI...

Page 45: ...the faceplate or the PXI trigger bus on the back plane by software command Syntax C C I16 TRIG_SetSoftTrg U8 Status Visual Basic TRIG_SetSoftTrg ByVal status As Byte As Integer Parameters Status Logi...

Page 46: ...ger_Route ByVal source As Long ByVal dest As Long ByVal halfway As Long As Integer Parameters source Source of trigger routing can be one of the following values Available value Description PXI_TRIG_V...

Page 47: ...plate PXI_TRIG_VAL_TRIG0 PXI trigger bus 0 PXI_TRIG_VAL_TRIG1 PXI trigger bus 1 PXI_TRIG_VAL_TRIG2 PXI trigger bus 2 PXI_TRIG_VAL_TRIG3 PXI trigger bus 3 PXI_TRIG_VAL_TRIG4 PXI trigger bus 4 PXI_TRIG_...

Page 48: ...ons A 2 5 TRIG_Trigger_Clear Description Clears the trigger routing setting Syntax C C I16 TRIG_Trigger_Clear Visual Basic TRIG_Trigger_Clear As Integer Parameters None Return Code ERR_NoError ERR_Boa...

Page 49: ...ault state after system boot of Logic Low Syntax C C I16 TRIG_GetSoftTrg U8 Status Visual Basic TRIG_GetSoftTrg status As Byte As Integer Parameters Status Returns the logic level of software trigger...

Page 50: ...source As Long dest As Long halfway As Long As Integer Parameters source Returns to the current source of trigger routing with possi ble values including Available Definition Defined Value PXI_TRIG_VA...

Page 51: ...ition Defined Value PXI_TRIG_VAL_NONE 0 PXI_TRIG_VAL_SMB 2 PXI_TRIG_VAL_TRIG0 111 PXI_TRIG_VAL_TRIG1 112 PXI_TRIG_VAL_TRIG2 113 PXI_TRIG_VAL_TRIG3 114 PXI_TRIG_VAL_TRIG4 115 PXI_TRIG_VAL_TRIG5 116 PXI...

Page 52: ...igned short minor1 unsigned short minor2 Visual Basic TRIG_GetDriverRevision major As Integer minor1 As Integer minor2 As Integer As Inte ger Parameters major Returns the major version number of the p...

Page 53: ...program The main BIOS setup menu is the first screen that you can navi gate Each main BIOS setup menu option is described in this chapter The Main BIOS setup menu screen has two main frames The left...

Page 54: ...hin a setup menu Enter Opens a sub menu or displays all available settings for a highlighted configuration option Esc Returns to the previous menu and shortcuts to the Exit menu from top level menus a...

Page 55: ...OS Information System Information Board Information System Date and Time Advanced CPU Configuration Memory Configuration Graphics Configuration USB Configuration TPM 2 0 Configuration Onboard Devices...

Page 56: ...version ME FW Version Info only ME firmware version BIOS boot Source Info only Boot BIOS primary or backup Feature Options Description Name Info only Displays model name Link Cap Info only PCI Express...

Page 57: ...e in seconds the system has been running in S0 state where the counter is cleared when the system is removed from the external power supply Power Cycles Info only Specifies the number of times externa...

Page 58: ...y Displays presence absence of Intel Virtualization Technology support SMX TXT Info only Displays presence absence of Intel SMX Technology support VT d Disabled Enabled Enables disables VT d function...

Page 59: ...Nominal and MMI O to Zero Configurable TDP Lock Disabled Enabled Configurable TDP Mode Lock sets the Lock bits on TURBO_ACTIVATION_RATIO and CONFIG_TDP_CONTROL When CTDP Lock is enabled Custom ConfigT...

Page 60: ...s Channel 0 slot 0 Info only Displays Channel 0 Channel 1 slot 0 Info only Displays Channel 1 Channel 2 slot 1 Info only Displays Channel 2 Feature Options Description GTT Size 2MB 4MB 8MB Selects Gra...

Page 61: ...evices USB Controllers Info only Displays USB Controller type USB Devices Info only Displays USB Devices XHCI Compliance Mode Disabled Enabled Enables Disables XHCI compliance mode XDCI Support Disabl...

Page 62: ...Clear Schedule an operation for the security device Platform Hierarchy Disabled Enabled Enable or disable storage hierarchy Storage Hierarchy Disabled Enabled Enable or disable storage hierarchy Endor...

Page 63: ...d Enables disables onboard I210 LAN controller UART Mode Control Configuration COM1 Control RS232 RS422 RS485 Selects serial port mode from among RS232 RS422 and RS485 Feature Options Description Abov...

Page 64: ...es disables onboard LAN1 Controller I219 wake capability Power up Mode Turn on Remain off Last state Turn on The machine starts automatically when the power supply is turned on Remain off The power bu...

Page 65: ...lays SEMA firmware build date SEMA Bootloader Info only Displays SEMA boot loader Build Date Info only Displays SEMA boot loader build date Feature Options Description BMC Flags Info only BIOS Select...

Page 66: ...ual voltage of the power rail VRTC V3P3S Info only Display actual voltage of the power rail V3P3S V3P3A Info only Display actual voltage of the power rail V3P3A V5S Info only Display actual voltage of...

Page 67: ...System 3 3V voltage 5V System Info only System 5V voltage 12V System Info only System 12V voltage VBAT Info only Battery voltage Feature Options Description Link Configuration Info only PCI Express li...

Page 68: ...le the PCI Express bus root port Max Link speed Auto Gen1 Gen2 Gen3 Sets maximum PCI Express link capability of the PCI Express bus root port PEG 0 1 1 Info only Link lanes and mode Enable root port A...

Page 69: ...ng DMI Link ASPM control Enabled Disabled Enable Disable Native Active State Power Management PCIE port assigned to LAN Info only PCIe port number assigned to LAN Compliance Test Mode Enabled Disabled...

Page 70: ...figuration Aggressive LPM support Enabled Disabled Enable PCH to aggressively enter link power state SATA Controller speed Default Gen1 Gen2 Gen3 Indicates the maximum speed the SATA controller can su...

Page 71: ...s set then this only limits access to BIOS Setup and is only asked for when entering BIOS Setup User Password Enter password If ONLY the User Password is set then this is a power on password and must...

Page 72: ...or disable boot with initialization of a minimal set of devices required to launch active boot option has no effect for BBS boot options CSM Sub menu See section B 8 2 on page 61 Boot Mode Select UEFI...

Page 73: ...EFI and Legacy Legacy only UEFI only Controls to which devices the system can boot Option ROM Execution Network Do not launch Legacy only UEFI only Controls execution of UEFI and Legacy PXE OpROM Stor...

Page 74: ...and resets system Save Changes Save changes made so far to setup options Discard Changes Discards changes made so far to setup options Default Options Restore Defaults Restores loads default values fo...

Page 75: ...powers on and boots the system into the OS moni tored by the independent controller If the main BIOS malfunctions for example as the result of corruption incurred by a failed update boot procedure is...

Page 76: ...64 Dual BIOS This page intentionally left blank...

Page 77: ...Support select Enabled 6 Under Network select Legacy 7 Under Storage select Legacy 8 Under Video select Legacy 9 Under Other PCI devices select Legacy 10 Press F10 and Enter to save and exit BIOS menu...

Page 78: ...66 Legacy Boot Mode Settings This page intentionally left blank...

Page 79: ...n removal of a chassis cover is required for user ser vicing See Getting Started on page 17 Turn off power and unplug any power cords cables Reinstall all chassis covers before restoring power To avoi...

Page 80: ...in a server room or computer room where access is Restricted to qualified service personnel or users familiar with restrictions applied to the location reasons therefor and any precautions required O...

Page 81: ...ction is our top priority Contact us should you require any service or assistance Shanghai Jianyi Technology Co Ltd www jytek com Website Service Telephone No Fax No Mailing Address 86 21 50475899 86...

Reviews: