background image

 

 

 

12 

4.开机步骤 

Boot step

 

 

1.

 

检查机箱是否与地面接触平稳 

Check if the chassis is in contact with the ground. 

 

2.

 

检查油水分离器水油液及气压是否满足运行要求 

To check whether the oil and gas pressure of oil water separator meets the 

requirements of operation 

 

3.

 

打开总电源开关 

Turn on the main power switch

 

 

4.

 

触摸屏幕    进入工作界面 

Touch screen          Enter the working interface

 

 

 

ON 

 

OFF 

Summary of Contents for JDCR5-01

Page 1: ...l tape winding machine U s e m a n u a l 2016 This manual is applicable to 2016 ex factory products Before using the product please be sure to read the manual carefully To ensure correct and safe use...

Page 2: ...following instructions and graphical symbols are used to indicate the attention and the important content of the safety related matters is identified in the note DANGER If you do not take appropriate...

Page 3: ...time Note for use Products should pay special attention to the following places to avoid the use of High humidity easy to form a condensed water A place where the temperature changes violently Place o...

Page 4: ...ds of physical and electronic manuals the electronic version of the manual can be obtained from the dealer Range of use This manual provides guidance for the operation of the product in order to match...

Page 5: ...step 5 14 Tape installation 6 17 Semi automatic operation using method 7 18 Automatic selection operation method 8 20 Automatic operation and use method 9 22 Homepage 10 23 Parameter setting 11 24 Se...

Page 6: ...duces the characteristics and application scope of the numerical control tape winding machine As follows Wrap around stop Dense winding 1 2 1 2 overlapping winding Pressure side winding Flowers wrappe...

Page 7: ...50MM 38MM 140MM 19MM Adhesive tape specification inside diameter 38MM outside small and equal to diameter 140MM width is less than or equal to 19MM if there are other tape size can be customized accor...

Page 8: ...on the maintenance to the following items WARNING Do not open the host in the state of power and contact with any part of the internal parts otherwise it will lead to electric shock accident Filling...

Page 9: ...8 In addition when filling oil assisted selection see replacing tape steps uniform oil As shown in the following figure...

Page 10: ...9 An auxiliary velocity set only valid administrator as shown below...

Page 11: ...y check the twist each screw is loose please fasten Note the yellow part of the swivel Oil water separator maintenance Use should give water separating gas filter to ensure timely drainage gas drying...

Page 12: ...to operate or wipe the screen no one will cause damage to the screen Periodic inspection In order to ensure that the host is in the best condition please check the following items regularly Work envi...

Page 13: ...the chassis is in contact with the ground 2 To check whether the oil and gas pressure of oil water separator meets the requirements of operation 3 Turn on the main power switch 4 Touch screen Enter th...

Page 14: ...13 5 Touch screen Select run mode WARNING To ensure that no foreign body in the machine is in order to prevent injury to the adult body before opening it...

Page 15: ...14 5 Tape installation 1 Touch screen Open the required working interface...

Page 16: ...the position of the rubber belt 4 When the adhesive tape is installed the adhesive tape head faces the machine direction into the adhesive tape fixing frame and then pull the tape head into the gap Wh...

Page 17: ...16 5 Replace the tape speed and change the position is arranged in the main control interface only valid administrator...

Page 18: ...l switch starts to work and the foot switch is loosened to stop working WARNING In the operation of the machine the hand must not exceed the warning line so as to avoid injury or death according to ad...

Page 19: ...ait until after the end of the program will automatically stop If there are special circumstances please press the emergency switch with the arrow to unlock the lock automatic stop Fixed reset button...

Page 20: ...ding touch the correct button will continue to be wound loosen and stop winding Winding number can be clicked directly to zero WARNING In the operation of the machine the hand must not exceed the warn...

Page 21: ...ll automatically stop automatically jump to the next program If there are special circumstances please press the emergency switch with the arrow to unlock the lock automatic stop Automatic operation p...

Page 22: ...winding 10 Automatically run a program the system will automatically jump to the next program no operation 10 sets of data followed by automatic cycle Winding number can be clicked directly to zero W...

Page 23: ...ntroduction Primary user interface only Administrator can operate on all interfaces User information display GUEST ADMIN User selection Touch screen parameters setting Operation interface Time setting...

Page 24: ...eed and transmission speed setting numerical deviation is smaller than the flower winding deviation can be realized overlapping winding Flower winding The winding speed and the transmission speed sett...

Page 25: ...proposed increase from 1000 11 Self learning In order to quickly set the parameters of the automatic operation the internal features added to the self learning Page introduction Using method 1 Set win...

Page 26: ...parameters will be displayed in the self learning display area 5 If there is an error in the automatic operation can be directly changed in the number of winding 12 Main control interface Page introd...

Page 27: ...th foreign body 150V AC voltage lower than 150V Reset parameters Touch master control interface alarm reset Power up again Transfer wheel not closed No air pressure Transfer enable not open Connecting...

Page 28: ...the transfer There is no sound transmission wheel Set the frequency is too high Connecting screw loose Reset parameters The rotary body nonhoming Parameter error Sensor failure Reset parameters Slow r...

Page 29: ...28 15 Safety tips Cordon Emergency stop button Look out In the operation of the line the foot must leave the foot switch or directly press the emergency stop switch in case of accident occurred...

Page 30: ...29 Improvement suggestions...