JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS23x, 34x, 43x
131
8.2.31
Home mode
Description: Selects the zero search that should start on power up.
A value of 13 will use sensor type 1, while a value of 14 will use sensor type 2.
8.2.32
Absolute encoder position
Description: This is the absolute magnetic encoder position.
It is only a single turn value in the range 0 to 1599. Please notice that this value is extract-
ed from the physical internal encoder which have an resolution of 0-1023 counts (10 bits)
therefore some values are truncated to the nearest count.
The background for doing this truncation is to align the operation range of the internal
encoder to the motors physical resolution (1600 mini steps per rev.)
8.2.33
SSI encoder value
Description: This is the actual encoder position data received from the external SSI encoder. This
value is typically gray-coded.
The firmware offers the possibility to do the Gray conversion but requires that some RxP
programming is done as this feature is only available as a RxP program command.
Example:
An SSI encoder is chosen using 25 bit data.
We want to sample and convert the SSI data value from register 47 and put the convert-
ed value into Register 61 (P2).
To get the actual value from the SSI encoder we use a special command 321. The new
data is placed in register 47. Now we want to convert the data from Gray-code to con-
ventional binary format.
To do this we use a Binary command instruction.
The command is 0x0C (12d)
From register 0x2F (47d)
To register 0x3D (61d)
25bits 0x19 (25d)
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
42
HOMEMODE
16bit
R/W
0,13,14
0
-
Zero Search Mode
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
46
ABSENCODER
16bit
R
(0-1599)
0
-
Abs. Encoder
Position
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
47
ABSENCODERSSI
16bit
R
(0-1023)
0
-
SSI Encoder value
Get the actual value from
the SSI enc oder
Convert from binary
TT2268GB
Summary of Contents for MIS23 Series
Page 6: ...6 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 29: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 27 ...
Page 56: ...54 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 116: ...114 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 188: ...186 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 260: ...258 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x ...
Page 335: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 333 ...
Page 341: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS23x 34x 43x 339 ...