JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
291
Objects used in the DSP-402 standard
Supported objects
The following table gives the additional object dictionary defined for DSP-402 support.
Name
Index
(hex)
Sub
Index
Type
Read
only
Default
Device data
Motor_type
6402
0
UNSIGNED16
X
9
Motor_catalog_number
6403
0
VISIBLE_STRING
X
MIS23x
(SMC75)
Motor_manufacturer
6404
0
VISIBLE_STRING
X
JVL A/S
http_motor_catalog_address
6405
0
VISIBLE_STRING
X
www.jvl.dk
Supported_drive_modes
6502
0
UNSIGNED32
X
37
Drive_catalog_number
6503
0
VISIBLE_STRING
X
MIS23x
(SMC75)
Drive_manufacturer
6504
0
VISIBLE_STRING
X
JVL A/S
http_drive_catalog_address
6505
0
VISIBLE_STRING
X
www.jvl.dk
Digital I/O
Digital_inputs
60FD
0
UNSIGNED32
X
Digital_outputs
60FE
0
UNSIGNED8
X
Digital_outputs_Physical_outputs
60FE
1
UNSIGNED32
Digital_outputs_Bit_mask
60FE
2
UNSIGNED32
Device Control
Abort_connection_option_code
6007
0
INTEGER16
Error_code
603F
0
UNSIGNED16
Control word
6040
0
UNSIGNED16
Status word
6041
0
UNSIGNED16
X
Quick_stop_option_code
605A
0
INTEGER16
Modes_of_operation
6060
0
INTEGER8
Modes_of_operation_display
6061
0
INTEGER8
X
Profile Position parameters
Position_actual_value
6064
0
INTEGER32
X
Target_position
607A
0
INTEGER32
Software_position_limit
607D
0
UNSIGNED8
X
2
Software_position_limit_
Min_position_limit
607D
1
INTEGER32
Software_position_limit_
Max_position_limit
607D
2
INTEGER32
Max_motor_speed
6080
0
UNSIGNED32
Profile_velocity
6081
0
UNSIGNED32
Profile_acceleration
6083
0
UNSIGNED32
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...