258
JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
12.1
Technical Data
12.1.1
EthernetIP for MAC or MIS - Technical specifications
Galvanic isolated, 100MBit, full duplex, 100Base-Tx, no termination necessary.
Network topology: Line, Star, Tree, Ring.
Supported Protocols:
•
DHCP - Dynamic Host Configuration Protocol
•
ACD - Address Conflict Detection
•
DLR - Device Level Ring (ring topology on device level)
Max. 100 m cable between slaves.
Connectors
(only applicable to MAC00-EIx)
:
• “PWR” (power) M12 connector 5pin male
• “I/O” M12 connector 8pin female
• “L/A IN” and “L/A OUT” (Ethernet) M12 connector 4pin D-coded female.
Supply
(only applicable to MAC00-EIx)
:
Supply voltage (CV): 12-48VDC Nominal (absolute max. 50V)
Current rating (CV): typical 150mA, max. 250mA
User I/O
(only applicable to MAC00-EIx)
:
User inputs:
Input impedance: 4.7k
Input current @24V: 5.1mA
Digital output current (HW rev. Up to 1.2): 10mA
Digital output current (HW rev. from 1.3): 15mA
12.1.2
EtherCAT® for MAC or MIS - Technical specifications
Galvanic isolated, 100MBit, full duplex, 100Base-Tx, no termination necessary.
Network topology: Line, Star, Tree, Ring (line recommended)
Pass through delay: <1
μ
s
Supported Protocols:
• SDO client and server side protocol
• CoE Emergency messages (CoE stack)
Max. 100 m cable between slaves.
Maximum number of slaves: 65535
Connectors
(only applicable to MAC00-ECx)
:
• “PWR” (power) M12 connector 5pin male
• “I/O” M12 connector 8pin female
• “L/A IN” and “L/A OUT” (Ethernet) M12 connector 4pin D-coded female.
Supply
(only applicable to MAC00-ECx)
:
Supply voltage (CV): 12-48VDC Nominal (absolute max. 50V)
Current rating @ 24V DC (CV): typical 150mA, max. 250mA
User I/O
(only applicable to MAC00-ECx)
:
User inputs:
Input impedance: 4.7k
Input current @24V: 5.1mA
Digital output current (HW rev. Up to 1.2): 10mA
Digital output current (HW rev. from 1.3): 15mA
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...