background image

8

Installation and Connection (WB-1540)

1.

Adhering the desiccant

Use a tape to adhere the supplied desiccant to the interior 
of the lower housing.

2.

Mount the lower housing

Mount the lower housing that is dismantled in Step 

2.

(

A

pg. 10) to the main housing unit using the 3 Screws A 

(M4 x 6).
Do so by aligning the position marks of the lower housing 
and the main housing unit.

3.

Mount the gasket and gasket gland

Mount the gasket and gasket gland that are dismantled in 
Step

1.

 (

A

pg. 10) of the housing disassembly procedure 

to the lower housing using the 6 Screws B (M4).

1.

Drill a hole into the wall.

Drill a hole (

R

 45 mm) for inserting the connection cable. 

(Refer to left fig.)

2.

Affix anchor bolts onto the wall.

• Affix 4 anchor bolts (M8, 35 mm and above) for attaching 

the housing. (Refer to left fig.)

• Affix an anchor bolts for attaching the safety wire, in the 

middle (about 60 mm from both ends) of the 2 upper 
anchor bolts, 30 mm from the top. (Refer to left fig.)

3.

Mount the safety wire and arm to the wall.

• Mount the safety wire attached to the housing, to the 

anchor bolts using the nut and wire.

• Use the nut and wire to mount the housing onto the wall.

Assembling the Housing

1.

2.

3.

Screw A (M4 x 6) x 3

Gasket

Gasket Gland

Screw B (M4) x 6

Lower Housing

Main Housing Unit

Desiccant

Safety Wire

Position Mark

CAUTION:

Fogging may occur when there are drastic temperature 
changes. In this case, continue using without turning off 
the power.

Pay attention when handling the desiccant in order to 
maintain its effectiveness.
• Do not remove it from the bag until you are about to use 

it.

• Do not wet it or touch it with wet hands.
• Assemble promptly upon adhering the desiccant.
• Be sure to replace the desiccant during maintenance.

CAUTION:

During assembly, ensure that wires and cables are not 
caught in the housing.

Do not exert force unnecessarily on the gasket or twist it 
during mounting.

Check to ensure that the gasket is in close contact with the 
camera.

Mounting the Housing to the wall 

202

176

60

152
126

63

45

12

30

1. 2.

Nut

Washer

Safety Wire

Installation Position

Anchor Bolt
(M8, 35 mm and above)

Summary of Contents for WB-1540

Page 1: ...ONS OUTDOOR HOUSING LST0267 001A WB 1540 WB 1550 For Customer Use Enter below the Serial No which is located on the body Retain this information for future reference Model No WB 1540 WB 1550 Serial No This instruction book is made from 100 recycle paper ...

Page 2: ...e 13 Do not overload wall outlets and extension cords as this can result in fire or electric shock 14 Never push objects of any kind into his appliance through cabinet slots as they mat touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the appliance 15 Do not attempt to service this appliance yourself as opening or rem...

Page 3: ...us avez acheté le produit Des amendes peuvent être infligées en cas d élimination incorrecte de ce produit conformément à la législation nationale Utilisateurs professionnels Si vous souhaitez éliminer ce produit visitez notre page Web www jvc europe com afin d obtenir des informations sur sa récupération Pays ne faisant pas partie de l Union européenne Si vous souhaitez éliminer ce produit faites...

Page 4: ... special techniques are necessary for installation Consult your dealer regarding installation and ensure that it is carried out by a specialist 䡵 Be sure to mount the safety wire for safety purposes If it falls it may cause injury or accidents 䡵 Taking vibrations mass and wind force into account ensure to mount in a location with sufficient strength using solid anchor bolts If reinforced or spiral...

Page 5: ... HOME 7 4 1 8 0 5 2 9 6 3 ENTER AUTO PAN OPTION 1 OPTION 2 CAMERA POSI TION AUTO PATROL CLOSE NEAR WIDE AUTO F 1 F 2 F 3 PAN TILT LENS CAMERA POSITION CAMERA POSITION REMOTE CONTROL UNIT RM P2580 ALARM POWER KEY LOCK TO CAMERA LED1 TB1 AC24V INPUT WB 1540 WB 1550 WB 1540 WB 1550 Main Board To TB1 Fuse T To VIDEO OUT TO CCU Terminal To CONTROL ALARM IN OUT Terminal To Insulated AC 24 V Power Supply...

Page 6: ...sassembling the Housing 2 1 Main Housing Unit Screw A M4 x 6 x 3 Lower Housing Gasket Gasket Gland Screw B M4 x 6 Safety Wire CAUTION Pay careful attention to store the dismantled parts and screws until assembly is complete to prevent them from being misplaced Mounting the Camera TK C625 3 1 2 4 Interior of Housing Notch Camera Mounting Bracket Safety Wire Main Board AC 24 V Output Cable To POWER ...

Page 7: ...ount 3 Connect other cables Connect the necessary cables supplied with the housing coaxial video cable alarm signal cable LAN cable etc to the corresponding terminals on the ceiling mount 4 Mount the camera s ceiling mount to the main housing unit Use the 4 screws supplied M4 x 20 to mount the ceiling mount to the main housing unit 5 Mount the camera to the ceiling mount Follow instructions in the...

Page 8: ...to left fig 3 Mount the safety wire and arm to the wall Mount the safety wire attached to the housing to the anchor bolts using the nut and wire Use the nut and wire to mount the housing onto the wall Assembling the Housing 1 2 3 Screw A M4 x 6 x 3 Gasket Gasket Gland Screw B M4 x 6 Lower Housing Main Housing Unit Desiccant Safety Wire Position Mark CAUTION Fogging may occur when there are drastic...

Page 9: ...le connection is complete close the cable connection cover and fasten 4 screws M3 x 12 removed in step 4 using the provided hexagon wrench Mounting the Housing to the Wall continued 4 9 5 8 6 7 8 T Not in use on this system Bind using a waterproof adhesive tape Bind with insulating tape T DC 12 V Power Cable Alarm Communication Cable Coaxial Video Cable Hole Waterproofing Screw M3 x 12 x 4 AC 24 V...

Page 10: ...rior of the combination camera A Turn the camera body cover in the direction as indicated in the left diagram When the camera body cover is tight and cannot be turned do so upon fastening the main unit B Dismantle the camera body cover C Dismantle the dome cover D Remove the rubber gasket and restore the dome cover and camera body cover to their original positions Disassembling the Housing 2 1 Saf...

Page 11: ...Camera TK C655 and TK C676 1 2 3 4 Interior of Housing Notch Camera Mounting Bracket Safety Wire Main Board AC 24 V Output Cable To POWER INPUT AC 24 V Terminal of Ceiling Mount Cables F Mark Ceiling Mount ScrewsSupplied 4 pcs Camera JVC Mark CAUTION Connect the communication cable to the ALARM IN OUT and CONTROL terminals if necessary For safety reasons ensure to cut off any excess cable and bind...

Page 12: ... 18 V terminal of VN C655 s ceiling mount 3 Connect other cables Connect the necessary cables supplied with the housing coaxial video cable alarm signal cable LAN cable etc to the corresponding terminals on the ceiling mount 4 Mount the camera s ceiling mount to the main housing unit Use the screws supplied 4 pcs to mount the ceiling mount to the main housing unit 5 Mount the camera to the ceiling...

Page 13: ...the safety wire and arm to the wall Mount the safety wire attached to the housing to the anchor bolts using the nut and wire Use the nut and wire to mount the housing onto the wall Assembling the Housing 3 2 1 Main Housing Unit Screw A M4 x 6 x 3 Lower Housing Gasket Screw B M4 x 8 Safety Wire Gasket Gland Desiccant Position Mark CAUTION Fogging may occur when there are drastic temperature changes...

Page 14: ...cable connection cover When cable connection is complete close the cable connection cover and fasten the 4 screws M3 x 12 removed in step 4 using the provided hexagon wrench Mounting the Housing to the Wall continued 4 9 5 6 7 8 8 Alarm Communication Cable Coaxial Video Cable AC 24 V Power Cable LAN Cable Male Screw M3 x 12 x 4 Bind using a waterproof adhesive tape Bind with insulating tape T Not ...

Page 15: ...prior notice 䡵 General Power Voltage AC 24 V 50 Hz 60 Hz Main Housing Unit Power Consumption 25 W During heater operating excluding camera Installation Location Outdoor general Ambient Temperature 20 I to 50 I when equipped with TK C676E TK C655E 20 I to 40 I when equipped with VN C655U Heater Operation Temperature Internal temperature Heater turns ON between 8 I 5 I Turns OFF between 20 I 5 I Amb...

Page 16: ... 2005 Victor Company of Japan Limited Printed in Japan LST0267 001A WB 1540 WB 1550 OUTDOOR HOUSING ...

Reviews: