2-6
Item
Mode
Adjustment procedure
Measuring
instrument &
Input signals
No.
Measuring point (
*
)
Adjustment parts (
-
)
Adjustment level (
+
)
2.7 ADJUSTMENT OF CCD
1) Select the “NEXT” button to display “V
SUB
voltage” on the title bar.
2) Adjust the VSUB with “
䊱
” and “
䊲
” buttons to
obtain the specified level at the measuring
point.
1
VSUB voltage
adjustment
Digital voltmeter
*
TP205 [PRO]
-
VSUB [CAT: DCREF,
Byte: 3]
+
Specified voltage on
the back of the CCD.
1) Select the “NEXT” button to display “Reset
voltage” on the title bar.
2) Adjust the VRGL with “
䊱
” and “
䊲
” but-
tons to obtain the specified level at the meas-
uring point.
*
TP214 [PRO]
-
VRGL [CAT: DCREF,
Byte:4]
+
Specified voltage on
the back of the CCD.
2
Reset voltage
adjustment
Oscilloscope
(H-rate:10:1)
Note:
For the specified voltage, check on the V
RGL
and V
SUB
codes shown on the back of the
CCD, and find out the proper value accord-
ing to the correlation table of the “How to
Find Specified Voltage” as shown below.
Note:
For the specified voltage, check on the V
RGL
and V
SUB
codes shown on the back of the
CCD, and find out the proper value accord-
ing to the correlation table of the “How to
Find Specified Voltage” appearing in the
lower part of this page.
How to Find Specified Voltage
Summary of Contents for TK-C400E
Page 21: ...Printed in Japan S T A VICTOR COMPANY OF JAPAN LIMITED TK C400U TK C400E TK C401EG No 6675 ...
Page 32: ...5 3 5 3 3 11 3 11 ...
Page 34: ...5 5 5 5 3 13 3 13 ...
Page 35: ...4 6 4 6 3 14 3 14 ...
Page 36: ...5 7 5 7 3 15 3 15 䡵 ICX054AK A SONY 1 3 inch CCD image sensor for NTSC color camera ...
Page 37: ...4 8 4 8 3 16 3 16 䡵 ICX055AK A SONY 1 3 inch CCD image sensor for PAL color camera ...