2.7 ADJUSTMENT OF VIDEO SIGNAL
1
White clip
adjustment
*
VIDEO OUT (75 ohm
Termination)
-
DAVREFY
[CAT: DCREF, Byte: 1]
1) Select the “NEXT” button to display “Con-
tour level” on the title bar.
2) Adjust the lens iris to obtain the specified level
at the measuring point.
1) Select the “NEXT” button to display “White
clip” on the title bar.
2) Turn the lens iris so that the wavefrom of
grayscele is saturated as shown left figure.
3) Adjust the DAVREFY with “
䊱
” and “
䊲
” but-
tons to obtain the specified level at the meas-
uring point.
2
Contour level
adjustment
*
VIDEO OUT (75 ohm
Termination)
-
LENS IRIS
LENS OPEN
+
0.77 Vp-p (110%)
Oscilloscope
(H-rate: 10:1) or
W.F.M.
Gray scale chart
(Just scan size)
+
0.56 Vp-p (80%)
+
0.7 Vp-p (100%)
*
VIDEO OUT (75 ohm
Termination)
-
VHAPGH
[CAT: FIELD, Byte: 3]
Oscilloscope
(H-rate: 10:1) or
W.F.M.
Gray scale chart
(Just scan size)
3) Adjust the VHAPGH with “
䊱
” and “
䊲
” but-
tons to obtain the specified level at the meas-
uring point.
2-6