19
5-2 Contents of the Function Menu Switches
5 SETTING OF THE FUNCTION MENU SWITCHES
[ ]: Factory setting
Function
Screens
Items
Set values
VTR mode 2
SUMMER TIME
[OFF]
setting
ON
Turns summer time compensation on or off.
OFF : Clock is not adjusted for summer (daylight saving) time.
ON
: Clock is adjusted for summer (daylight saving) time.
TERMINAL
[SERIES]
SEL 1
EXT
C.ADJ
Select the signal to be input or output to the [SERIES/CLOCK IN·OUT]
terminals on the rear panel.
SERIES : Set to this position to input or output a series recording signal.
EXT
: Set to this position to start or stop the recording with the VCR
activation signal input from an external control device.
C.ADJ
: Set to this position to input or output a clock reset signal.
TERMINAL
[WARN.]
SEL 2
REC
REC REMAIN
[OFF]
180S
360S
VTR mode 1
INDEX
[OFF]
setting
SEARCH
ON
Enables or disables the Index Search function.
OFF : The index search function is disabled.
ON
: When an alarm-recorded tape is put in the FF or REW Shuttle Search
mode, the VCR searches for the nearest recorded index code (VISS
signal) and engages playback at the indexed position.
When an alarm-recorded tape is fast-forwarded or rewound, the VCR
searches for the nearest index code and enters the Stop mode at the
indexed position.
CAMERA SW
[OFF]
1 FIELD
1 FRAME
Sets the camera switching interval for output to an external sequential switcher
during recording.
OFF
: No camera switching signal is output.
1 FIELD : Set to this position to switch the camera every 1 field.
1 FRAME : Set to this position to switch cameras every 1 frame.
TAPE END
[OFF]
BUZZER
ON
Turns the Tape End buzzer on or off.
OFF : The buzzer does not sound at tape end.
ON
: When the tape reaches the position set with the <REC REMAIN> menu
function switch during recording (tape end, or 3 minutes or 6 minutes
before the tape ends during 6H mode ), a buzzer sounds.
To stop the buzzer sound, press the [REW] button, [EJECT] button or
[POWER] button.
When the mode is changed, the buzzer sound stops.
WARNING
[OFF]
BUZZER
ON
Turns the warning buzzer on or off.
OFF : The buzzer does not sound.
ON
: The buzzer sounds.
Setting
Record modes
6H
L18H
L30H
OFF
Tape end
Tape end
Tape end
180S
3 minutes
9 minutes
15 minutes
360S
6 minutes
18 minutes
30 minutes
Sets the timing to process tape end before the actual tape end. This menu
switch setting is effective in the 6H to L30H Record modes. For the 48H to
240H modes, set with <COUNT END>. The following operations are executed
at the timing set with this menu switch.
• The tape end signal is output from the rear panel's [TAPE END] terminal.
• The series recording signal is output from the rear panel's [CLOCK/SERIES
OUT] terminal (with the TERMINAL SEL 1> function menu switch set to
"SERIES").
• The tape end buzzer sounds (with the <TAPE END BUZZER> function menu
switch set to "ON").
• "End" is shown on the counter display.
The set values (180S/360S) are for the 6H mode. The relation between the
recording mode and the recording time is shown below.
These values should be used as a reference only. Actual values may differ depending on
the tape used.
Select the signal output from the rear panel’s [WARNING/REC OUT] terminal.
WARN. : Set to this position to output a warning signal. The warning signal is
output if an abnormality occurs in tape transport or mechanism
operation.
REC
: Set to this position to output a recording mode signal (+12 V) in the
Record mode.