NX-MD1R/NX-MD1
1-22
Turn over the body and disconnect the card wires
from connectors CN408, CN521 and the flexible wire
from CN407 on the MD servo board.
Remove the two screws
A
attaching the main board.
Slide the MD servo board in the direction of the
arrow to release the two joints
a
with the single
flame.
Shorting round
b
on the pickup in the body.
Disconnect the flexible harness from connector
CN321 and CN451 on the underside of the MD servo
board. Then remove the MD servo board.
1.
2.
3.
Removing the MD servo board
(See Fig.1 and 2)
Remove the four screws
B
on both sides of the
mechanism cover.
Remove the screw
B'
on the earth wire of the
mechanism cover.
Move the mechanism cover toward the front to
disengage the front hook of the mechanism cover
from the internal loading assembly (Joint
c
). Then
remove the mechanism cover upward.
1.
2.
3.
Removing the mechanism cover
(See Fig.3)
<MD mechanism section>
Fig.1
Fig.2
Fig.3
A
A
MD servo board
(Bottom side)
CN408
CN407
Joint a
Joint a
CN521
Joint c
Hook
Joint c
Mechanism cover
B
B
Earth wire
B'
MD servo board
CN321
CN451
Pickup
Shorting round b