MX-S6MD
1-36
RUNNING MODE
Indication the [CAUTION !] when abnormal
1.Setting the TEST MODE
2.Release the TEST MODE
This running mode is a mode by which the recording is compulsorily deleted with ALL-ERASE after
U-TOC is written when the recording of MD ends, and the recording is repeated again.
This TEST MODE is continue recording (loop recording), it is for recording stop when MD end.
This TEST MODE is only can use manual operation recording [MD REC PAUSE]. CD synchro recording
(CD MD REC,BEST HIT REC,1CD MD REC) is not operate correctly.
1:Setting normal speed recording mode by pressing together [POWER key], [2 key] and [STOP key]
of Remote controller.
2:If normal speed mode is default then change to high speed mode, press [HIGH SPEED CD>MD key] of
main body before recording start.
3:Once change to high speed mode, TEST MODE is continue until release.
4:Return to normal speed recording mode, it should release the TEST MODE then resetting the
TEST MODE.
(REMARKS) Case of CD high speed recording : After setting TEST MODE, if it need setting
CD play mode or repeat mode. Press [HIGH SPEED CD > MD key] setting high speed
mode. RUNNING MODE is start by REC STANDBY (indicate [RUNNING MODE] on LCD)
at [MD REC PAUSE key] then playback the CD.
(During recording, LCD indicate [RUNNING MODE])
Abnormal detection dine of the stability power supply(REG.) at CPU [SAFETY1~3] port (IC801:6,7,9pin),
when system CPU (IC801) supply voltage (US D5.6V) is normal condition.
Watching the abnormal at POWER ON condition, if detect the abnormal indicate [CAUTION!] and come
under stability power supply (8V/10V or 12V OR 6V), and indicate [DATA(HEX)] of the abnormal port
voltage then power off to forcibly.
Detect the abnormal condition of stability power supply is next.
[8V/10V] : SAFETY1 port (Power supply of full color LED/Power supply of CD mechanism)
[12V] : SAFETY2 port (Power supply for tuner module REG, MD mechanism REG, volume IC,
LPF IC and CD/MD SELECTOR)
[6V] : SAFETY3 port (Power supply for MD mechanism, power supply for OPT. module, power
supply for CD/OPT SELECTOR)
Test mode is release by POWER OFF.
When detect the abnormal condition of CD mechanism, indicate [CAUTION ! ] and come under
condition and back light is change to [RED] forcibly.
Indication when mechanism abnormal condition.
[CD INITIAL] : Abnormal condition when mechanism initialize after power cord to connect to
AC outlet then power to ON.
[CD MECH] : Abnormal condition when mechanism initialize at return operation, it is
Sub Tray Load/Unload operation, Lifter shift operation, or CAM operation
are defect.
[CD MECHA 5V] : Abnormal condition at 5V (LSI) internal the CD mechanism.
1.Detect the abnormal condition of stability power supply
2.Abnormal detection of CD mechanism
(REMARKS) Safety port voltage at detect the abnormal condition.
DATA(HEX)
3FF~2D0
2CF~12C
12B~000
PORT voltage
5.0~3.52V
3.515~1.456V
1.46V~0V
Detect condition
Abnormal (Power off at 1sec. forcibly)
Normal
Abnormal (Power off at 3sec. forcibly)