JVC LST1153-001A Instruction Manual Download Page 13

3

To prolong the service life of the RM-HP790DU/RM-

HP790DE, do not use it or store it in the following places.

A place subject to extremely high or low temperatures.

A place subject to excessive vibration.

A place subject to excessive dust.

A place subject to high humidity.

A place near to a strong source of noise.

Do not apply strong vibrations or impact to the RM-

HP790DU/RM-HP790DE during installation or 
transportation.

If the supply voltage is too high or low, the service life of 

the RM-HP790DU/RM-HP790DE may be reduced or it may 
not be able to provide an optimum performance.

Do not connect or disconnect the camera cable connector 

while the RM-HP790DU/RM-HP790DE is ON.

After turning the RM-HP790DU/RM-HP790DE OFF, wait 

at least 10 seconds before turning it ON again.

Noise may interfere with the video when the RM-

HP790DU/RM-HP790DE is installed near a source of strong 
magnetism, such as a radio or TV transmitting antenna, 
power transformer or motor.

While the values set by using the menus are retained in 

the memory even after the unit is turned off, those set using 
the front panel switches and controls are retained for about 
10 days only and then the factory-set defaults are reset.

As the LCD contrast is reduced at low temperatures, it 

should be re-adjusted before use in such conditions.
(

A

 Page 26 [CONTRAST])

When a transceiver or cellular phone is used near to a 

RM-HP790DU/RM-HP790DE or to a camera connected to it, 
noise may interfere with the video. However, this is not a 
malfunction.

When an intercom is used, radio interference may 

occasionally affect any system that is connected to the RM-
HP790DU/RM-HP790DE.

In such a case the INTERCOM G (GND) terminal 

provided to the RM-HP790DU/RM-HP790DE should be 
grounded.

In a multiple camera setup, if the adjustments made to the 

different cameras deviate significantly, the cameras may not 
be able to function satisfactorily. Be sure to adjust the 
cameras

 

accordingly before using them with the RM-

HP790DU/RM-HP790DE.

Use camera cables with standard lengths, as specified. 

Otherwise, the camera cable compensation may not be able 
to work efficiently.

RM-HP790DU/RM-HP790DE can be connected to the 

following e

q

uipment:

GY-HM790 series (HD Memory Card Camera Recorder)

KA-M790G (Multicore Remote Adapter)

KA-790G (Studio Adapter)

VF-HP790G (Studio Viewfinder)

Functions not available on the camera cannot be controlled 
from this unit.
(

A

 Page 29 [Operable Camera Features])

If the RM-HP790DU/RM-HP790DE is rack-mounted, be 

sure to insert ventilated panels above and below it in order to 
improve ventilation, Do not stack two RM-HP790DU/RM-
HP790DE units or place any object on top of a RM-
HP790DU/RM-HP790DE unit.

In addition, make sure to keep surrounding temperature of 
this unit below 40

f

 during use.

To save power consumption, turn the RM-HP790DU/RM-

HP790DE OFF when it is not in use.

Precautions for Proper Use

Summary of Contents for LST1153-001A

Page 1: ...se Enter below the Serial No which is located on the body Retain this information for future reference Model No RM HP790DU Serial No Please read the following before getting started Thank you for purchasing this JVC product Before operating this unit please read the instructions carefully to ensure the best possible performance In this manual each model number is described without the last letter ...

Page 2: ...GUARDS and certain items may not apply to all appliances 3 All warnings on the product and in the operating instructions should be adhered to FOR USA 15 Never push objects of any kind into this appliance through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the appliance 16 Do not attempt ...

Page 3: ... équilatéral est destiné à alerter l utilisateur sur la présence d une tension dangereuse non isolée dans le boîtier du produit Cette tension est suffisante pour provoquer l électrocution de personnes Le point d exclamation àl intérieur d un triangle équilatéral est destiné à alerter l utilisateur sur la présence d opérations d entretien importantes au sujet desquelles des renseignements se trouve...

Page 4: ... BLUE must be connected to the terminal which is marked with the letter N or which is coloured BLACK The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED POWER SYSTEM Connection to the mains supply This unit operates on voltage of 230 V AC 50 Hz RM HP790DE Caution for AC Power Cord FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFU...

Page 5: ...uld be handed over to the applicable collection point for the recycling of electrical and electronic equipment for proper treatment recovery and recycling in accordance with your national legislation By disposing of this product correctly you will help to conserve natural resources and will help prevent potential negative effects on the environment and human health which could otherwise be caused ...

Page 6: ...tention should be paid to small children 䡵 Do not place anything containing water on the unit such as a vase plant pot glass cosmetics or chemicals If water gets inside the unit it may lead to fire or electric shock 䡵 Do not insert foreign objects into the unit If any metal object or flammable item gets into the unit through the ventilation openings etc it may lead to fire or electric shock Mainta...

Page 7: ...nes Radio oder TVSenders eines Transformators Motors usw können Bild und Tonstörungen auftreten Bitte stellen Sie das Gerät in solchen Fällen in größerer Entfernung zur Störquelle auf dieses Gerät stimmt mit den gültigen europäischen Richtlinien und Normen bezüglich elektromagnetischer Verträglichkeit und elektrischer Sicherheit überein Die europäische Vertretung für die Victor Company of Japan Li...

Page 8: ...auft haben Für die nicht fachgerechte Entsorgung dieses Abfalls können gemäß der Landesgesetzgebung Strafen ausgesprochen werden Geschäftskunden Wenn Sie dieses Produkt entsorgen möchten besuchen Sie bitte unsere Webseite http www jvc eu um Informationen zur Rücknahme des Produkts zu erhalten Andere Länder außerhalb der Europäischen Union Wenn Sie dieses Produkt entsorgen möchten halten Sie sich d...

Page 9: ... Schutzkontaktstecker bietet auf irgendeine Weise außer Kraft zu setzen 8 Um das Gerät während eines Gewitters oder für einen längeren unbeaufsichtigten Zeitraum zu schützen ziehen Sie den Netzstecker aus der Steckdose und trennen Sie die Antenne oder das Kabelsystem ab Dadurch vermeiden Sie Produktschäden die als Folge eines Blitzeinschlags oder Stromstosses auftreten können WICHTIGE SICHERHEITSH...

Page 10: ...e besonders auf kleine Kinder 䡵 Stellen Sie keine wasserhaltigen Gegenstände auf dem Gerät ab beispielsweise Vase Blumentopf Gläser Kosmetika oder Chemikalien Tritt Wasser in das Innere des Geräten ein kann dies einen Brand oder einen Kurzschluss verursachen 䡵 Stecken Sie keine Fremdkörper in den Gerät Dringen metallische oder brennbare Gegenstände durch die Belüftungsschlitze o ä in den Gerät ein...

Page 11: ...ck Boden angebracht werden Wird das Rack teilweise genutzt bauen Sie die Teile von unten nach oben ein Die schwerste Komponente sollte stets unten im Rack eingebaut werden Ist das Rack mit stabilisierendem Zubehör ausgestattet montieren Sie zunächst diese Stabilisatoren bevor Sie das Gerät in das Rack einbauen oder warten Technische Daten Allgemein Zulässiger Temperaturbereich bei der Lagerung 20f...

Page 12: ... GY HM790U GY HM790CHU GY HM790E GY HM790CHE and Multicore Remote Adapter KA M790G Maximum 100m of HD analog component signals can be transferred You can use the optional camera cable VC P110 series to extend the distance between the camera and the remote control unit up to 100m and transfer the HD analog component signals There is no need to prepare a separate power source as the power to the stu...

Page 13: ...hen a transceiver or cellular phone is used near to a RM HP790DU RM HP790DE or to a camera connected to it noise may interfere with the video However this is not a malfunction 䡵 When an intercom is used radio interference may occasionally affect any system that is connected to the RM HP790DU RM HP790DE 䡵 In such a case the INTERCOM G GND terminal provided to the RM HP790DU RM HP790DE should be gro...

Page 14: ...the color bars signal A Page 12 Adjustments for Genlock Operation G F1 to F4 function buttons and indicator light 2 Each of these buttons can turn the function assigned to it alternately ON and OFF A Page 15 Function Buttons H LCD display This panel shows the SHUTTER and GAIN settings as well as the functions assigned to the function buttons This panel is also used to show menus and various operat...

Page 15: ...operation If the adjustment has not been done correctly the LCD display H shows an error message The light in this button also lights up when the FAW Full time Auto White balance adjustment function of the camera is functioning R WHITE W BAL B A PRESET switch 2 This switch switches the white balance control setting between the value stored in Memory ABB AUTO 2 that stored in Memory AAB AUTO 1 and ...

Page 16: ...put signals from these connectors can be switched between Y PB PR G B R using the Signal Serect switch on the connected camera or by using the menu setup of the camera G COMPOSITE VIDEO Signal Output Connector This connector outputs VBS composite video signal H HD SD SDI INPUT OUTPUT SDI signal input and output connectors These are HD SD SDI signal input output connectors SDI signal that is input ...

Page 17: ...790DU RM HP790DE are available in four lengths as listed below A menu setup is required according to the cables in use A Page 12 Camera Cable Length Setup Memo If it is required to extent the cable use the KA 280 extension connector The total cable length should not exceed 100 meters VC P110 5 meters VC P112 20 meters VC P113 50 meters VC P114 100 meters Camera Cable Optional ...

Page 18: ...he clamp filter as close to connector as possible Models with an E suffix are for the European market and the UL Listing mark is not applicable Example of Basic Connection REMOTE Y G PB B PR R ACHIN AC120V 60Hz TALLY PGM PVW C INTERCOM AUX VIDEO INPUT GENLOCK INPUT VIDEO OUTPUT H RTS C G COMPOSITE VIDEO CAMERA CABLE HD SD SDI INPUT OUTPUT 1 GY HM790U GY HM790CHU GY HM790E GY HM790CHE Studio Viewfi...

Page 19: ...MANUAL MANUAL PRESET PRESET FAW FAW AW A AW A AW B AW B PART PART PRESET PRESET LEVEL LEVEL IRIS MODE IRIS MODE FULL FULL PRE PRE SET SET FULL FULL 1 LEV IR AUT IS 3dB 3dB 6dB 6dB ALC ALC LOLUX LOLUX VARIABLE VARIABLE LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL GAMMA GAMMA DETAIL DETAIL KNEE POINT KNEE POINT AUTO AUTO KNEE KNEE BLACK BLACK COMPRESS COMPRESS STRETCH STRETCH WHITE BALANCE MODE WHITE BALANCE...

Page 20: ...IN GAIN 18dB 18dB 0dB 0dB 3dB 3dB 6dB 6dB 9dB 12dB 12dB 15dB 15dB MANUAL MANUAL PRESET PRESET FAW FAW AW A AW A AW B AW B PART PART PRESET PRESET LEVEL LEVEL IRIS MODE IRIS MODE FULL FULL PRE PRE SET SET FULL FULL 1 LEV IR AUT IS 3dB 3dB 6dB 6dB ALC ALC LOLUX LOLUX VARIABLE VARIABLE LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL GAMMA GAMMA DETAIL DETAIL KNEE POINT KNEE POINT AUTO AUTO KNEE KNEE BLACK BLACK ...

Page 21: ... Connect the camera to the RM HP790DU RM HP790DE using a proper connection method 2 Press the POWER switch of the RM HP790DU RM HP790DE to ON Memo When an item is controllable from both the RM HP790DU RM HP790DE and the camera the control from the camera is defeated Functions not available on the camera cannot be controlled from this unit When connecting the RM HP790DU RM HP790DE to the camera do ...

Page 22: ...d waveform monitor Be sure to use an underscanned video monitor It is not permitted to genlock the system components using a VCR playback signal Before phase adjustment wait a little for the phases of the connected components to stabilize Preparation 1 Press the BARS button to output the color bar signal The button light should light up 2 Output the built in color bar signal of the SEG from the pr...

Page 23: ... then turn the SHUTTER control knob to adjust the SC COARSE value to 0 90 180 or 270 3 After the coarse adjustment press the SHUTTER control knob to move the cursor J back to A1C SC COARSEB then press the SHUTTER control knob to display A1D SC FINEB 4 Press the SHUTTER control knob to move the cursor J to the currently set value then turn the SHUTTER control knob to adjust the SC FINE value from 1...

Page 24: ...amp on the camera does not blink or light when either the camera or the RM HP790DU RM HP790DE are switched off When the CALL button of the camera is pressed the CALL button of RM HP790DU RM HP790DE blinks in red The TALLY lamp on the front panel lights when signals are applied to the TALLY terminals on the rear panel 䡵 The factory settings vary depending on the model RM HP790DU Contact supply mode...

Page 25: ... MENU button to display the functions assigned to the function buttons for about 3 seconds in up to 7 characters per function as shown in the figure below Memo When BLACK STRETCH and BLACK COMPRESS are assigned to two of the F1 to F4 buttons it is not permitted to switch the two functions ON simultaneously It is not permitted to switch both ALC EEI and LOLUX ON 1 This function is unavailable when ...

Page 26: ... or in VARIABLE mode for fine adjustments A Page 25 SHUTTER A Page 29 Operable Camera Features The AVARIABLEB function is unavailable when connected to GY HM790 series Memo Values that are not available on the camera cannot be set on this unit A Page 29 Operable Camera Features The shutter speed displayed on the RM HP790DU RM HP790DE may be slightly different from the actual shutter speed of the c...

Page 27: ...dBB or A18 dBB When the variation step is set to A1 0 dBB the gain can be varied from 1dB to 18dB in 1dB steps A Page 25 V GAIN STEP and V GAIN MAX The camera lens iris can be adjusted from the RM HP790DU RM HP790DE Memo When the light in the IRIS AUTO MANU button is not lit the iris control is set to Auto mode in which the iris level is controlled automatically according to the light intensity Th...

Page 28: ...e R and B gain levels using their respective controls Memo The white paint operation is not capable of making large variations in the R and B gain levels The white paint operation is turned OFF automatically when the auto white balance adjustment is starte MANUAL white balance adjustment This function enables the manual adjustment of the white balance using the R and B gain controls Use an oscillo...

Page 29: ... AUTO 4Z BACK 5Z BACK 6 LCD MODE 8 EXIT 6A CONTRAST 6B BACKLIGHT 6Z BACK 5 to NORMAL to 5 OFF ON 5 OPERATION Netted items are saved in the scene file 5A SHUTTER 5C V GAIN MAX 5D GAIN LOW STEP VARIABLE 9 0 dB 12 0 dB 18 0 dB 5B V GAIN STEP 0 1 dB 1 0 dB 3 dB 0 dB 3 dB 6 dB 9 dB 12 dB 15 dB 18 dB 5E GAIN MID 3 dB 0 dB 3 dB 6 dB 9 dB 12 dB 15 dB 18 dB 5F GAIN HIGH 3 dB 0 dB 3 dB 6 dB 9 dB 12 dB 15 dB...

Page 30: ... knob to move the cursor J to the position of the currently set value 5 Turn the control knob SHUTTER to adjust the setting 6 Press the SHUTTER control knob to move the cursor J back to the item 7 Turn the SHUTTER control knob to move the cursor J to A2Z BACKB 8 Press the SHUTTER control knob to return to the previous menu 9 After completing the setup move the cursor J to A8 EXITB and press the SH...

Page 31: ...ing Values Function 1A SD H PHASE 1 128 to 0 to 127 Adjustment of the Horizontal sync phase of genlocking 1B HD H PHASE 1024 to 0 to 1023 Adjustment of the Horizontal sync phase of genlocking 1C SC COARSE 1 0 90 180 270 Coarse adjustment of the color phase of genlocking Use a vectorscope etc 1D SC FINE 1 128 to 0 to 127 Fine adjustment of the color phase which should be performed after completing ...

Page 32: ...now the SHUTTER control knob should be pressed again 8 To store data in a selected file turn the SHUTTER control knob to move the cursor J moves to AEXECUTEB 9 Press the SHUTTER control knob to write data in a selected file and return to the previous display 䡵 Loaging the data in a file To read previously written data in step 3 move the cursor J to A3A LOAD FILEB then perform the same operations a...

Page 33: ...terned object AUTO 1 Automatic adjustment of the detail enhancement frequency according to the object 4E SKIN DETAIL OFF ON ON OFF setting of the skin tone detail function which displays natural wet skin colors by reducing detail enhancement on the skin areas OFF Skin tone detail function is deactivated ON Skin tone detail function is activated 4F AUTO KNEE OFF ON ON OFF setting whether the AUTO K...

Page 34: ...ed video signal NORMAL Standard gain STRETCH Stretches the signals of the dark areas in the image to enhance them and clarify the difference between the bright and dark areas COMPRESS When the captured image is bright in overall and has few contrast The gain of the dark areas is compressed to provide contrast 4M ASPECT RATIO 1 4 3 16 9 LETTER Sets the picture size of the video signal 4 3 4 3 scree...

Page 35: ...ary the gain up to 18 0 dB 5D GAIN LOW 3 dB 1 0 dB 3 dB 6 dB 9 dB 12 dB 15 dB 18 dB Selects the gain value when the front panel GAIN switch is set to the ALOWB position 5E GAIN MID 3 dB 1 3 dB 6 dB 9 dB 12 dB 15 dB 18 dB Selects the gain value when the front panel GAIN switch is set to the AMIDB position 5F GAIN HIGH 3 dB 1 3 dB 6 dB 12 dB 15 dB 18 dB Selects the gain value when the front panel GA...

Page 36: ...ues you have set press the control knob now LCD MODE Menu No Item Setting Values Function 6A CONTRAST 5 to NORMAL to 5 Adjusts the contrast of the LCD display 6B BACKLIGHT OFF ON Adjusts the setting of the backlight of the LCD display OFF Backlight is turned off ON Backlight is turned on 6Z BACK Return to the previous display SYSTEM Menu No Item Setting Values Function 7A CONTRAST CANCEL EXECUTE R...

Page 37: ...ages 21 to 26 Other status settings are reset as shown below 7A SYSTEM RESET EXECUTE NOW INITIALIZING JUST A MOMENT STR CMP OFF 0 dB ALC LUX Status Setting Default values IRIS AUTO MANU button MANUAL W BAL switch Switch position WHITE PAINT button OFF WHITE PAINT switch A B ch Central value of the control R ch B B ch Central value of the control R ch WHITE PAINT switch B ch Central value of the co...

Page 38: ... be started in this mode INVALID ENTRY W BAL MANUAL The white balance adjustment is set to manual mode by the WHITE AUTO button Auto white balance adjustment cannot be started in this mode INVALID ENTRY BARS ON The BARS button is pressed Press the BARS button so that the lamp in it turns off then retry operation Error Messages Displayed Message Cause Check Point AUTO WHITE A B ERROR LOW LIGHT The ...

Page 39: ... dB 3 12 dB 3 15 dB 3 18 dB 3 24 dB ALC EEI 3 ALC 3 VARIABLE LOLUX OFF ON SHUTTER 1 OFF 3 1 100 or 1 120 3 2 1 250 3 1 500 3 1 1000 3 1 2000 3 1 4000 3 1 10000 3 VARIABLE TALLY 3 PREVIEW 3 CALL 3 Function GY HM790 series 3 Available Not available BARS OFF 3 ON 3 DETAIL CONTOUR OFF 3 ON 3 DETAIL LEVEL 3 DETAIL V H 3 DETAIL FRQ 1 LOW 3 MIDDLE 3 HIGH 3 AUTO AUTO KNEE OFF 3 ON 3 KNEE POINT 3 COLOR MAT...

Page 40: ...is A50B 2 Setting is configured from RM HP790DU RM HP790DE regardless of the status of the FULL AUTO switch Menu items that are disabled 3 CINEMA is forcibly set to AOFFB To adjust MATRIX make ues of the menu on the camera 4 GAMMA is fixed at the menu setting value of the camera before connecting to the remote control However when the menu setting value is AOFFB GAMMA will be forcibly set to ASTAN...

Page 41: ...have the assigned function Check the camera functions again and assign the proper functions to the F1 to F4 buttons A P 25 white balance adjustment cannot be started Is the W BAL switch set to AAB or ABB Is FAS or FAW ON which is indicated by the lighting of the AUTO light A P 18 The white balance adjustment will not complete Are the color temperature filters and lighting conditions appropriate Do...

Page 42: ... connectors 2 outputs Tally RM HP790DU Contact supply DC 10 V 3 mA or more RM HP790DE Voltage supply AC 6 3 V DC 5 to 24 V Non switching between AC and DC Intercom RM HP790DU 2 line system 10 dB 220 K unbalanced RTS The RTS terminals are not designed to accept a voltage supply RM HP790DE 2 line system 10 dB 600 K balanced Remote 5 0 V p p HD SD SDI INTPUT HD SDI SMPTE292M compliant 720p 60 50 1080...

Page 43: ...2 483 465 340 to 370 306 283 203 272 CALL TALLY INTERCOM LEVEL FULL AUTO F1 SHUTTER GAIN F2 F3 MENU SHUTTER GAIN PAINT AUTO B R W BAL AUTO MANU WHITE MASTER BLACK POWER I O IRIS STEP SHUTTER MENU PUSH ON DOWN UP VARIABLE PUSH ON HIGH LOW B A PRESET CLOSE OPEN MID DOWN UP F4 BARS REMOTE CONTROL UNIT RM HP790 REMOTE HD SD SDI Y G PB B PR R INPUT OUTPUT AC H IN 230V H 50Hz TALLY PGM PVW C INTERCOM AU...

Page 44: ...2010 Victor Company of Japan Limited LST1153 001A RM HP790DU RM HP790DE REMOTE CONTROL UNIT ...