(No.MA244)1-15
4.2
Service mode
Set up
Press POWER ON [SEL] [POWER] [CD EJECT] together more than 2 sec.
UP,DW button to select
SEL button to determination
For next operation, service mode is stop automaticaly.
1. No input signal (key operation) more than 5 sec.
2. press other key without SEL,UP,DOWN.
3. ACC to OFF.
DEL EPROM
EEPROM clear
CD ERROR
CD error history call change by FF button E1 to TOTAL
DEL CD
CD error history clear
MAIN TEMP
Templature indication of main board
VERSION
Micon version indication