(No.MA453<Rev.003>)1-23
4.9.3 Error codes of panel mechanism
* As for two columns of the beginning of the error code, as for error contents, two columns of middle, number of the pulse counts, last
two columns are a purpose position and movement directions.
Note: "**" of the above error code is the number of the pulse counts at the time of the error outbreak.
Detail
Error code
(Service mode)
It is time-out during movement to the closed position.
0B**11
It is time-out during 5 degrees tilt movement.(open direction)
0B**20
It is time-out during 5 degrees tilt movement.(close direction)
0B**21
It is time-out during 10 degrees tilt movement.(open direction)
0B**30
It is time-out during 10 degrees tilt movement.(close direction)
0B**31
It is time-out during 15 degrees tilt movement.(open direction)
0B**40
It is time-out during 15 degrees tilt movement.(close direction)
0B**41
It is time-out during 20 degrees tilt movement.(open direction)
0B**50
It is time-out during 20 degrees tilt movement.(close direction)
0B**51
It is time-out during 25 degrees tilt movement.(open direction)
0B**60
It is time-out during 25 degrees tilt movement.(close direction)
0B**61
It is time-out during 30 degrees tilt movement.(open direction)
0B**70
It is time-out during 30 degrees tilt movement.(close direction)
0B**71
It is time-out during movement to the open position.
0B**80
It is position error during close position stop.
0C0011
It is position error during 5 degree tilt position stop.
0C0020
It is position error during 10 degree tilt position stop.
0C0030
It is position error during 15 degree tilt position stop.
0C0040
It is position error during 20 degree tilt position stop.
0C0050
It is position error during 25 degree tilt position stop.
0C0060
It is position error during 30 degree tilt position stop.
0C0070
It is position error during open position stop.
0C0080
Detect abnormal voltage (1)
F3**XY
Detect abnormal voltage (2)
F5**XY
Detect abnormal voltage (3)
F7**XY
Detect abnormal voltage (4)
F8**XY
Error contents
When assumed last two columns XY;, as for X, as for purpose position,
Y, is a movement direction.
Time out
Position error by
the external force
Abnormal voltage (1)
Abnormal voltage (2)
Abnormal voltage (3)
Abnormal voltage (4)
code
OB
OC
F3
F5
F7
F8
Purpose position
CLOSE
5 degrees
10 degrees
15 degrees
20 degrees
25 degrees
30 degrees
open
X
1
2
3
4
5
6
7
8
Movement direction
Open direction
Close direction
Y
0
1