1-20 (No.MA272)
Name
Function
Comment
RS
CTRL
MODE
AR
ARTTE
TEMP
VOLT
FLAGS
RSOC
NAC
CACD
CACT
LMD
AI
TTE
TTF
SI
STTE
MLI
MLTTE
SAE
AP
TTECP
CYCL
CYCT
CSOC
not used
not used
TEMP contain the reported die temperature.
VOLT contain the reported battery voltage measured on the BAT pin.
RSOC reports the nominal available capacity as a percentage of the
last measured discharge value (LMD).
NAC increments during charge(Vsrp > Vsrn) if Voltage > EDVF
threshold and decrement during discharges (Vsrp > Vsrn).
CACD reports available capacity in the battery.
CACT reports available capacity in the battery, compensated for
both discharge rate and temperature.
LMD is the measured discharge capacity of battery from full to empty.
AI reports the magnitude of the average current through the sense
resistor
TTE reports calculated time-to-empty at the measured discharge rate.
TTF reports calculated time-to-full at the measured charge rate.
SI reports measured standby current through the sense resistor.
STTE reports calculated time-to-empty at the measured standby
current value.
MLI reports the measured Maximum load current through the sense
resistor.
MLTTE reports calculated time-to-empty in minutes at the Maximum
measured discharge rate.
SAE is the calculated energy available from the battery.
AP is the calculated power delivered during a discharge.
TTECP is the time-to-empty on minutes with a constant power load.
CYCL is the cycle count since the learning cycle.
CYCT is the cycle count since a full reset.
OSOC reports the compensated available capacity as a percentage
of the last measured value(LMD).
The Sense Resistor Value [mill ohm]
Device Control Register [Hex]
Device Control Register [Hex]
At Rate [mA]
At Rate Time-to Empty [min]
Reported Temperature [K]
Reported Battery Voltage [mV]
Status Flags [Hex]
Relative Start-of-Charge [%]
Nominal Available Capacity [mAh]
Discharge Compensated NAC [mAh]
Temperature Compensated CACD [mAh]
Last Measured Discharge [mAh]
Average Current [mA]
Time-to-Empty [min]
Time-to-Full [min]
Standby Current [mA]
Standby Time-to-Empty [min]
Max Load Current [mA]
Max Load Time-to-Empty [min]
Available Energy [mWh]
Average Power [mW]
Time-to-Empty At Constant Power [min]
Cycle Count Since Learning Cycle [cycles]
Cycle Count Total [cycles]
Compensated State-of-Charge [%]
Content of gas gauge data