1-10
KD-SX883
Adjustment method
Test instruments required adjustment
1.Digital oscilloscope (100MHz)
2.AM Standard signal generator
3.FM Standard signal generator
4.Stereo modulator
5.Electric voltmeter
6.Digital tester
7.Tracking offset meter
8.Test Disc JVC : CTS-1000
9.Extension cable for check
Standard measuring conditions
Power supply voltage DC14.4V(10.5
–
16V)
Load impedance 4 (4 to 8 allowance)
How to connect the extension cable for adjusting
Standard volume position
Balance and Bass & Treble volume : Indication "0"
FM
MW
Dummy load
Exclusive dummy load should be used for AM,and FM.
For FM dummy load, there is a loss of 6dB between SSG output
and antenna input. The loss of 6dB need not be considered
since direct reading of figures are applied in this working
standard.
EXTGS004-26P
1 – 3 87.5MHz – 108.0MHz
531kHz – 1602kHz
Frequency Band
Line-out Level / Impedance:
KD-SX975 : 4.0 V 20 k load (full scale)
KD-SX875 : 2.0 V 20 k load (full scale)
BBE:OFF
EXTGS004-26P
Summary of Contents for KD-SX883
Page 29: ...1 29 KD SX883 M E M O ...
Page 39: ... M E M O ...
Page 40: ...KD SX883 ...
Page 53: ...3 13 KD SX883 M E M O ...