Adjustment method
Test instruments required adjustment
1.Digital oscilloscope (100MHz)
2.AM Standard signal generator
3.FM Standard signal generator
4.Stereo modulator
5.Electric voltmeter
6.Digital tester
7.Tracking offset meter
8.Test Disc JVC : CTS-1000
9.Extension cable for check
Standard measuring conditions
Power supply voltage DC14.4V(10.5~16V)
Load impedance 20Kohm(2 Speakers connection)
Output level Line out (Vol. MAX)
How to connect the extension cable for adjusting
Standard volume position
Balance and Bass & Treble volume : Indication "0"
Loudness : OFF
FM
MW
LW
Dummy load
Exclusive dummy load should be used for AM,and FM.
For FM dummy load, there is a loss of 6dB between SSG output
and antenna input. The loss of 6dB need not be considered
since direct reading of figures are applied in this working
standard.
EXTGS004-26P
EXTGS004-26P
1~3 87.5MHz~108.0MHz
522kHz~1620kHz
144kHz~279kHz
Frequency Band