(No.YA010)1-41
4.8.9 SUB SCREEN ADJUSTMENT
Item
Measuring
instrument
Test point
Adjustment part
Description
SUB SCREEN
CONTRAST
Signal
generator
Remote
control unit
[2. V/C]
11. TWN_CONT
(1) Set the screen to the multi (twin) mode.
(2) Receive the black and white signal (color off) to both
right and left screen.
(3) Select 2. V/C.
(4) Set the initial setting value of < 11. TWN_CONT >.
(5) If the contrast of both screen are not the best with the
initial setting value, make fine adjustment of the < 11.
TWN_CONT > until you get the optimum contrast.
(6) Press the [MENU] key to memorize the adjustment
values.
SUB SCREEN
COLOUR &
TINT
Signal
generator
Remote
control unit
TP-47R
TP-E
[CRT SOCKET
PWB]
[2. V/C]
12. TWN_COL
13. TWN_TNT
PAL COLOUR
(1) Set the screen to the multi (twin) mode.
(2) Receive PAL full field colour bar signal (75% white)
to the sub screen.
(3) Select 2. V/C.
(4) Set the initial setting value of < 12. TWN_COL >.
(5) Connect the oscilloscope between TP-47R and
TP-E at the CRT SOCKET PWB.
(6) Adjust < 12. TWN_COL > so that the voltage
difference between white and red 5V.
(7) Press the [MENU] key to memorize the adjustment value.
SECAM COLOUR [Except model for UK]
(1) Set the screen to the multi (twin) mode.
(2) Receive SECAM colour bar signal (75% white) to the
sub screen.
(3) Select 2. V/C.
(4) Set the initial setting value of < 12. TWN_COL >.
(5) Connect the oscilloscope between TP-47R and
TP-E at the CRT SOCKET PWB.
(6) Adjust < 12. TWN_COL > so that the voltage
difference between white and red become 0V.
(7) Press the [MENU] key to memorize the adjustment value.
NTSC COLOUR
(1) Set the screen to the multi (twin) mode.
(2) Input NTSC3.58 full field colour bar signal (75%
white) from the EXT terminal to sub screen.
(3) Select 2. V/C.
(4) Set the initial setting value of < 12. TWN_COL >.
(5) Connect the oscilloscope between TP-47R and
TP-E at the CRT SOCKET PWB.
(6) Adjust < 12. TWN_COL > so that the voltage
difference between white and red become -2V.
(7) Press the [MENU] key to memorize the adjustment value.
NTSC TINT
(1) Set the screen to the multi (twin) mode.
(2) Input NTSC3.58 full field colour bar signal (75%
white) from the EXT terminal to sub screen.
(3) Select 2. V/C.
(4) Set the initial setting value of < 13. TWN_TNT >.
(5) Connect the oscilloscope between TP-47R and
TP-E at the CRT SOCKET PWB.
(6) Adjust < 13. TWN_TNT > so that the voltage
difference between white and yellow 1V.
(7) Press the [MENU] key to memorize the adjustment value.
Initial setting value
Colour system
Colour system
Colour system
Colour system
PAL
SECAM
NTSC 3.58
9
9
9
SUB SCREEN COLOUR
Adjustment value
PAL
NTSC 3.58
SECAM
+5V
0V
-2V
SUB SCREEN COLOUR ADJUSTMENT VALUE[V]
Initial setting value
NTSC 3.58
35
SUB SCREEN TINT
Adjustment value
NTSC 3.58
+1V
SUB SCREEN TINT ADJUSTMENT VALUE[V]