No. 51828
HV-L29PRO
29
Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment of
H. CENTER
Signal
generator
Remote
control unit
3.H-CENT.
13. Receive a circle pattern signal.
14. Select 3.H-CENT and set the initial setting value.
15. Adjust H-CENT to make
C=D
.
16. Press the MENU/OK key and memorize the set value.
Adjustment
of H.SIZE
4.H-SIZE
17. Receive a cross-hatch signal.
18. Select 4.H-SIZE and set the initial setting value.
19. Adjust H-SIZE and make sure that the horizontal screen size
of the picture size is in the bellow table.
20. Press the MENU/OK key and memorize the set value.
21. Input a NTSC VIDEO signal (60Hz) from the EXT terminal, and
make sure that the horizontal screen size is in the below table.
22. Press the MENU/OK key and memorize the set value.
Adjustment
of EW-PIN
6.EW-PIN
23. Select 6.EW-PIN and set the initial setting value
24. Adjust EW-PIN and make the 2nd.vertical lines at the left and
right edges of the screen straight. Also make sure that the 3rd
vertical lines are straight.
25. Press the MENU/OK key and memorize the set value.
C
D
Straight
ZOOM
ASPECT
MODE
ADJ. ITEM
REGULAR
ZOOM
16 : 9
H-SIZE
92%
(FIXED)
(FIXED)