background image

HA-W500RF (EG)/(EK)

2 (No.70270)

Safety Precautions

1. This  design  of  this  product  contains  special  hardware  and  many  circuits  and  components specially  

for  safety  purposes.    For  continued  protection,  no  changes  should  be  made  to  the  original  design  
unless  authorized  in  writing  by  the  manufacturer.    Replacement  parts  must  be  identical  to  those  
used  in  the  original  circuits.    Services  should  be  performed  by  qualified  personnel  only.

2. Alterations  of  the  design  or  circuitry  of  the  product  should  not  be  made.    Any  design  alterations  of  

the  product  should  not  be  made.    Any  design  alterations  or  additions  will    void  the manufacturer`s  
warranty  and  will  further  relieve  the  manufacture  of  responsibility  for  personal  injury  or  property  
damage  resulting  therefrom.

3. Many  electrical  and  mechanical parts  in  the  products  have  special  safety-related  characteristics.    

These  characteristics  are  often  not  evident  from  visual  inspection  nor  can  the  protection  afforded  
by  them  necessarily  be  obtained  by  using  replacement  components  rated  for  higher  voltage,  
wattage,  etc.    Replacement  parts  which  have  these  special  safety  characteristics  are  identified  in  
the  Parts  List  of  Service  Manual.    Electrical  components  having  such  features  are  identified  by  
shading  on  the  schematics  and  by  (    )  on  the  Parts  List  in  the  Service  Manual.    The  use  of  a  
substitute  replacement  which  does  not  have  the  same  safety  characteristics  as  the  recommended  
replacement  parts  shown  in  the  Parts  List  of  Service  Manual  may  create  shock,  fire,  or  other  
hazards.

4. The  leads  in  the  products  are  routed  and  dressed  with  ties,  clamps,  tubings,  barriers  and  the  

like  to  be  separated  from  live  parts,  high  temperature  parts,  moving  parts  and/or  sharp  edges  
for  the  prevention  of  electric  shock  and  fire  hazard.    When  service  is  required,  the  original  lead  
routing  and  dress  should  be  observed,  and  it  should  be  confirmed  that  they  have  been  returned  
to  normal,  after  re-assembling.

5. Leakage  currnet  check  (Electrical  shock  hazard  testing)

After  re-assembling  the  product,  always  perform  an  isolation  check  on  the  exposed  metal  parts  
of  the  product  (antenna  terminals,  knobs,  metal  cabinet,  screw  heads,  headphone  jack,  control  
shafts,  etc.)  to  be  sure  the  product  is  safe  to  operate  without  danger  of  electrical  shock.
Do  not  use  a  line  isolation  transformer  during  this  check.

Plug  the  AC  line  cord  directly  into  the  AC  outlet.    Using  a  "Leakage  Current  Tester",  measure  
the  leakage   current  from  each  exposed  metal  parts  of  the  cabinet , particularly  any  exposed  
metal  part  having  a return  path  to  the  chassis,  to  a  known  good  earth  ground.  Any  leakage  
current  must  not  exceed  0.5mA  AC  (r.m.s.)

Alternate  check  method
Plug   the  AC  line  cord  directly  into  the  AC  outlet.    Use  an  AC  voltmeter  having,  1,000  ohms  
per  volt or  more  sensitivity  in  the  following manner. Connect  a  1,500    10W  resistor  paralleled by 
a 0.15  F AC-type  capacitor  between an  exposed  
metal  part  and  a  known  good  earth  ground.
Measure the  AC  voltage across the resistor  with the 
AC voltmeter. 
Move the  resistor  connection  to eachexposed metal  
part,  particularly  any  exposed  metal part having  a  
return  path  to the  chassis, and meausre the  AC  
voltage  across  the  resistor. Now, reverse the plug in 
the AC outlet and repeat each measurement. voltage 
measured Any must  not exceed 0.75 V  AC  (r.m.s.). 
This  corresponds  to  0.5 mA  AC  (r.m.s.). 

Warning

1. This equipment has been  designed  and  manufactured  to  meet  international  safety  standards.
2. It  is  the  legal  responsibility  of  the  repairer  to  ensure  that  these  safety  standards  are  maintained.
3. Repairs  must  be  made  in  accordance  with  the  relevant  safety  standards.
4. It  is  essential  that  safety  critical  components  are  replaced  by  approved  parts.
5. If  mains  voltage  selector  is  provided,  check  setting  for  local  voltage.

Good earth ground

Place this 
probe on 
each exposed
metal part.

AC VOLTMETER
(Having 1000 
ohms/volts,
or more sensitivity)

1500     10W

0.15   F  AC TYPE

Summary of Contents for HA-W500RF EK

Page 1: ...ft Plug adaptor x 1 converts 3 5 mm dia stereo mini plug to a 6 3 mm dia standar d stereo phone plug General Specifications System Radio Frequency UHF stereo Modulation Frequency modulation Carrier frequency 863 865 MHz Usable area distance to reach Approx 100m 328 ft using JVC measurements systems Frequency response 30 Hz 15 000 Hz Distortion Less than 4 at 1 kHz Contents Headphones HA W500RF Pow...

Page 2: ...t should be confirmed that they have been returned to normal after re assembling 5 Leakage currnet check Electrical shock hazard testing After re assembling the product always perform an isolation check on the exposed metal parts of the product antenna terminals knobs metal cabinet screw heads headphone jack control shafts etc to be sure the product is safe to operate without danger of electrical ...

Page 3: ... R 3 2 Remove the screw 4 and pull up the driver unit ass y L 2 and R 3 3 At channel L Remove the screw 5 and insulation washer 6 and pull up the charge print circuit board 7 4 Remove the switch knob 8 5 Remove the screw 9 and remove the battery door 10 from the housing ass y L 12 6 Remove the battery 11 from the housing ass y L 12 7 At channel R Remove the main print circuit board 13 from the hou...

Page 4: ...R40 1M D3 4148 Q68550 Q7 3904 R41 75k Q8 3904 C38 100u 27k R22 27k R23 C22 12p C75 0 01u 2k7 R19 VR2 100k IC4A LM393 or NJM2903M LM393 or NJM2903M 3 2 1 8 4 2k7 R20 S1a SW SPDT R42 50K S1b SW SPDT C73 220u R14 100K C32 220u VR1b 100k VR1a 100k C76 100p L9 15nH C36 2U2 C37 2U2 T2 R31 2K2 C44 10u C77 1p C78 1p C83 10p L1 15nH C881000p C28 4U7 C26 1U C29 33U C31 10U IC1 7201 15 3 1 2 VI VO GND Q9 550...

Page 5: ...Receiver Headphones CHARGE P C BOARD TOP 3 Measurement Condition AC IN Transmitter Receiver Headphones Distance 1m 3 28ft Reference input signal 1kHz 300mVp p sine wave Hedaphone volume control MAX Surface shows the B power supply shows the ground shows others ...

Page 6: ...G PCB 2A 2A 2A 3A 2A 3D 4C 4C 4C 4C 3D 3C 2B 2B 2B CHG PCB CHG PCB Symbol R37 R38 R39 R40 R41 R42 R43 R44 R45 R46 R47 R48 R49 R50 VR1 VR2 VR3 VR4 VR5 JP1 JP2 JP3 JP4 C21 C22 Location CHG PCB CHG PCB CHG PCB CHG PCB CHG PCB CHG PCB CHG PCB CHG PCB CHG PCB CHG PCB CHG PCB 3A 4B 4C 4C 1B 1C 3D 3D 1B 2C Symbol C23 C24 C25 C26 C27 C28 C29 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C40 C41 C42 C43 C44 C45 ...

Page 7: ... ass y Inside of the housing R Antenna Inside of the head band ass y Natural shielded lead Green shielded lead Green shielded lead Red shielded lead Natural shielded lead Natural shielded lead Speaker Rch Inside of the housing L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 PLL LPF1 PILOT DET LPF2 PILOT DET LPF2 ST IND VCO CHECK Rch OUT Lch OUT Vcc RIPPLE FILTER ...

Page 8: ...lem arise in this transmitter unit have to change the transmitter unit itself due to avoid the law of radio regulation Parts marked A ave safety parts When replacing be sure to use the specified one Parts marked A are safety parts When replacing be sure to use the specified one Receiver Headphones Transmitter Receiver Headphones ANT FILTER UHF MODULE ANT IF VB VT 18 FM STEREO RADIO IC2 CXA1538M RF...

Page 9: ... Ass y 1 with battery terminal 3 J34075 001 Housing R Ass y 1 4 J34076 001 Battery Door 1 with protector 5 J34077 001 Driver Unit L Ass y 1 with protector 6 J34078 001 Driver Unit R Ass y 1 7 J47146 001 Swihch knob 1 8 J47144 001 Ear Pad 2 9 J46514 001 Rechargeable Ni Cd batteries 1 10 QYSPSPU1411M Screw 8 11 QYSPSFT1403M Screw 4 Receiver Headphones 10 Mechanical Parts List Parts marked A are safe...

Page 10: ...01202005 Poly Bag 1 for AC Adaptor 12 Packing Materials Parts List A Item No Parts No Parts Name Q ty Description A 8 J5500 114A Instructions 1 for EG model A 8 J5500 115A Instructions 1 for EK model 9 BT 54008 4 European Guarantee Certificate 1 A 10 J47126 001 AC Adaptor 1 for EG model A 10 J47127 001 AC Adaptor 1 for EK model 11 J47143 001 Connection cord 1 12 J46517 001 Plug adaptor 1 13 Access...

Page 11: ...HA W500RF EG EK No 70270 11 MEMO ...

Page 12: ...No 70270 HA W500RF EG EK Printed in Japan 200209 VICTOR COMPANY OF JAPAN LIMITED COMMUNICATION NETWORK BUSINESS UNIT AV MULTIMEDIA COMPANY 1644 Shimotsuruma Yamato Kanagawa 242 8514 Japan ...