1-14 (No.YF173)
3.2.4 DISASSEMBLY OF [18] MONITOR ASSEMBLY
z
CAUTIONS
(1) During the procedure, be careful in handling the LCD
MODULE and other parts. Pay special attention not to
damage or soil the monitor screen.
If fingerprints are left on the screen, wipe them with clean
chamois leather or a cleaning cloth.
z
Removing MONITOR ASSEMBLY
(1) Turn the HINGE UNIT ASSY 90
°
, and Remove the
M.COVER ASSY by removing the six hooks (L4a-f).
(2) Release the lock of the connector (CN18a), and remove
the HINGE UNIT by lifting it up.
NOTE18a:
During the procedure, be careful in handling the FPC.
(3) Release the lock of the connector (CN18b), and pull out
the FPC.
(4) Remove the screw (3), and remove the MONI BOARD
ASSY .
NOTE18b:
When attaching the MONITOR BOARD ASSY, be
careful to avoid any misalignment or unevenness of
the parts underneath.
Attach the MONITOR BOARD ASSY by lifting up the
MONITOR CASE as the KNOB (CURSOR) that is at-
tached to the BOARD sticks out toward the LCD
screen.
(5) Remove the SHEET (M.REF), LIGHT GUIDE, SHEET
(M.DIFF) and the SHEET(BEF).
(6) Remove the SHILD CASE(MONI), LCD MODULE and
the LCD CASE.
NOTE18c:
During the procedure, handle the three parts (LCD
CASE, LCD MODULE, and SHILD CASE(MONI)) to-
gether.
z
Removing HINGE UNIT ASSEMBLY
(1) Remove the screw (4), and remove the H.COVER(U,L).
NOTE18d:
During the procedure, be careful in handling the mag-
net.
When attaching, set the negative pole outside as
shown in the figure. Be careful when removing as
there is no marking.
NOTE18e:
During the procedure, be careful in handling the FPC.
NOTE18f:
The FPC is rolled around the axis of rotation of the
HINGE ASSY 2.5 rounds (2.5times).
The connecting side to the MONITOR BOARD ASSY
is placed inside.