background image

Instructions

MICRO HD CAMERA

DZ-VCA3U

LYT1053-001B

Serial No.

Model No.

Summary of Contents for DZ-VCA3U - 3-ccd Micro Hdtv Camera

Page 1: ...Instructions MICRO HD CAMERA DZ VCA3U LYT1053 001B Serial No Model No ...

Page 2: ... 57 7 D mm and its weight to only 100g High resolution A total of three VGA 1 3 inch CCDs are used for each R G and B With digital signal processing this camera is able to produce extremely high horizontal resolution 750 TV lines and vertical resolution 700 TV lines The aspect ratio is 4 3 System construction HDTV studio standard compliant with ITU R Rec BT 709 3 sync signals are used allowing rec...

Page 3: ...se mobile cart when crossing a threshold or excessively thick carpet Be extra careful when transporting this product with mobile cart Sudden stops excessive force and travelling on uneven surfaces may cause the product and cart to topple ATTENTION Follow and obey all warnings and instructions marked on your product and its operating instructions For your safety please read all the safety and opera...

Page 4: ...ith the equivalent safety requirements of this equipment may lead to a reduced level of safety with the resulting system Consideration relating to the choice of accessories shall include use of the accessory in the vicinity of the patient evidence that the safety of the accessory has been certified in accordance with the appropriate IEC 60601 1 and or IEC 60601 1 1 harmonized national standard WAR...

Page 5: ...disposing of it See page 6 When discarding equipment environmental problems must be considered and the local rules or laws govern ing the disposal must be followed strictly USE 1 Accessories To avoid personal injury Do not place this product on an unstable cart stand tripod bracket or table It may fall causing serious injury to a child or adult and serious damage to the product Use only with a car...

Page 6: ...product at least once a year STERILIZATION The camera head with camera cable and endoscope adapter can be sterilized with ethylene oxide EO EO gas parameters are as follows Ethylene oxide gas 10 EO and 90 Inert gases Temperature 40 C to 60 C 104 F to 140 F EO gas intensity 600mg L Sterilization time 2 to 4 hours Desorption Aeration Aerator 50 C and more than 18 hours In room temperature it is requ...

Page 7: ...not suitable for use in the presence of a flammable anaesthetic mixture with air or oxygen or nitrous oxide Precautions Safety precautions L Do not damage or modify the power cable Doing so could result in current leakage or electric shock L To protect the camera and avoid electric shock hazards always disconnect the power cord of the camera control unit from the AC outlet when the camera is not i...

Page 8: ...t to a specially trained service personnel 2 Connect the optional endoscope adapter DZ E3U or DZ E33U to lens mount of camera head Remove the cap from the lens mount when cap is con nected to the lens mount align the screws of lens mount and endoscope adapter and turn the lens mount clockwise to tighten it To Camera control unit Adapter Endoscope Inspection and maintenance The product and its comp...

Page 9: ...ation transformer cabinet is corroded please approach your local authorized dealer to have it replaced L Connection example AC IN NTSC OUT SXGA OUT GBR DV Y PB PR Y C S VBS HD OUT GENLOCK IN OUT Endoscope Commercially available Endoscope adapter Optional Connector Cap Connector Camera head DT V1900CG Optional SR W7MAU Optional W VHS Front To each equipment Isolation transformer AA V31U Optional Vi...

Page 10: ...t level controller section Set output level automatically or manually Set adjustment combining gain and shutter here 4 WHITE BALANCE white balance control sec tion Adjust white balance automatically or manually 5 Menu control section Display menu to do various settings 6 Mode control section ON OFF setting of enhance freeze and colour bar ON I O OFF POWER CAMERA SETTING RED BLUE WHITE BALANCE AUTO...

Page 11: ... signals VBS compos ite video signals The power supply for IEEE1394 interface is not available from DV connector 5 GENLOCK IN OUT sync signal input output Input output of composite sync signal for external sync menu based switching 6 SXGA OUT SXGA output section Output of progressive scan GBR signal SXGA output signal cannot be displayed on the DT V1900CG Use the monitor that is compliant with the...

Page 12: ...e suffi cient ON I O OFF POWER CAMERA SETTING RED BLUE WHITE BALANCE AUTO MANUAL ON OFF ENHANCE FREEZE BAR MENU SETTING GAIN SHUTTER OUTPUT LEVEL ADJUST AUTO MANUAL GAIN SHUTTER OUTPUT LEVEL ADJUST AUTO MANUAL 3 4 2 1 1 GAIN switch AUTO Adjusts gain automatically In this mode the GAIN UP GAIN DOWN button 3 and SHUTTER UP SHUTTER DOWN button 4 operations are disabled MANUAL Set to this position whe...

Page 13: ...MANUAL SETTING RED BLUE WHITE BALANCE AUTO MANUAL 7 5 6 5 WHITE BALANCE switch 6 SETTING button 7 R B button AUTO When set to this position the camera is automatically set to a pre adjusted white balance To automatically readjust the while balance use SETTING button 6 MANUAL When adjusting the white balance manually set to this position Adjustment is done through R B volume 7 ...

Page 14: ...d with UP DOWN CURSOR button When the right arrow or left arrow appears on the right of the menu item it indicates that the item can be selected with LEFT RIGHT CURSOR button 12 ON I O OFF POWER CAMERA SETTING RED BLUE WHITE BALANCE AUTO MANUAL ON OFF ENHANCE FREEZE BAR MENU SETTING GAIN SHUTTER OUTPUT LEVEL ADJUST AUTO MANUAL ENHANCE FREEZE BAR 8 9 10 11 MENU switch ON The menu is displayed on th...

Page 15: ... display INDICATION2 menu Set the display on the top right of HD OUT and SXGA OUT screen Selection items and functions are as follows Selection item Function DATE TIME Displays date and time TIME Displays only time OFF No display INDICATION3 menu Set the display on the bottom right of NTSC OUT screen Selection items and functions are as follows Selection item Function DATE TIME Displays date and t...

Page 16: ...t of the date to be changed the numbers will blink and use the UP DOWN button to set the new value TIME sub menu Use the LEFT RIGHT button to select the part of the time to be changed the numbers will blink and use the UP DOWN button to set the new value DATE FORM sub menu Use the LEFT RIGHT button to select one of the following three formats year month day day month year month day year The month ...

Page 17: ...icture on the monitor screen until it turns white In this case high precision white balance cannot be obtained While watching the monitor shoot a white object with full screen under the same lighting condition as actual shooting Set the WHITE BALANCE switch to AUTO When you press and hold SETTING button AUTO WHITE will blink at the upper left corner of the screen When white balance adjustment is c...

Page 18: ...ion transformer AA V31U 3 Switch on isolation transformer AA V31U power switch 4 Switch on DZ VCA3U power 5 Switch on W VHS power Insert W VHS tape and make sure that it can record 6 Switch on the power of monitor Check that picture taken by camera can be displayed on the monitor 7 Operate each device according to its operating procedure Note Consult JVC service personnel or authorized dealer when...

Page 19: ...rth ground Earth ground TYPE OF APPLIED CF EQUIPMENT Equipotentiality Video output Symbols indicated on this equipment have the following meanings 1 Sync signal output 2 Sync signal output 3 Shutter speed control signal 4 Shutter speed control signal 5 Shutter speed control signal 6 Control signal input 7 DC 15V output 8 DC 5V output 9 GND 10 7 5V output 11 B signal input 12 GND 13 G signal input ...

Page 20: ...TV lines TYP HD Y output SXGA output L S N 52dB L Sensitivity F6 8 2000 lx L Minimum subject illuminance 5 lx L Sync system Internal sync external sync L External sync signal input Composite sync signal of 0 3Vp p 75 ohms BNC x 1 ITU R Rec BT 709 3 HDTV standard compliant L Color bar Full color bar L Contour correction Horizontal dual edged 7 step variable Vertical dual edged 7 step variable L Ele...

Page 21: ... Front Bottom Side Front Rear AC IN NTSC OUT SXGA OUT GBR DV Y PB PR Y C S VBS HD OUT GENLOCK IN OUT ON I O OFF POWER CAMERA SETTING RED BLUE WHITE BALANCE AUTO MANUAL ON OFF ENHANCE FREEZE BAR MENU SETTING GAIN SHUTTER OUTPUT LEVEL ADJUST AUTO MANUAL 280 140 300 Camera control unit ...

Page 22: ...er requirements 120 V AC 60 Hz L Power consumption 43W L Dimensions 476 mm W x 148 mm H x 366 mm D L Weight 10 kg Endoscope Adapter DZ E3U Focal length 24 mm Camera Mount C Mount Sterilization Applicable for EO Weight 51g 1 8 oz Zoom endoscope adapter DZ E33U Focal length 13mm to 26mm Camera Mount C Mount Sterilization Applicable for EO Weight 102g 3 6 oz TECHNICAL AND SERVICE ASSISTANCE JVC offer...

Page 23: ...es dealer or nearest service counter listed in Service Counter Guides Warranty and after sales service L Escape clause 1 Using this product for medical treatment is the decision and responsibility of medical doctors Our company is not responsible for treatment result using this product 2 Our company is not responsible for any damage to this product due to removal servicing inspection and modifi ca...

Page 24: ...DZ VCA3U COPYRIGHT 2002 VICTOR COMPANY OF JAPAN LTD U Printed in Japan VICTOR COMPANY OF JAPAN LIMITED 0902 MN SW SW ...

Reviews: