(No.YD085)1-7
2.3
Jig RCU mode
This unit uses the following two modes for receiving remote con-
trol codes.
(1) User RCU mode:Ordinary mode for use by the user.
(2) Jig RCU mode: Mode for use in production and servicing.
When using the Jig RCU, it is required to set the unit to the Jig
RCU mode (the mode in which codes from the Jig RCU can be
received). As both of the above two modes are stored in the EE-
PROM, it is required to set the unit back to the User RCU mode
each time that an adjustment is made or to check that the neces-
sary operations have been completed.These modes can be set
by the operations described below.
Note:
•
When the unit is set to Jig RCU mode and when the unit
is under Jig RCU mode, the remote control unit attached
to product operates only in "Remote Control Code 1".
Since the unit is in "Remote Control Code 3" when it is
shipped and just after its batteries are changed, "Re-
mote Control Code 3" needs to be changed to "Remote
Control Code 1."
•
Confirm the RCU mode when exchanged parts. Since
some SERVICE PARTS sets the unit to the Jig RCU
mode as initial setting. Therefore please set the unit to
the user RCU mode after replacing the EEPROM.
Fig.2-3a User/Jig RCU mode
2.3.1 Changing Remote Control Code
(1) Slide the TV/CABLE/SAT/DVD switch to DVD.
(2) Press the number key "1" of the remote control unit while
pressing the "SET UP" button of the remote control unit.
Then,press the "ENTER" button, and then release the
"SET UP" button.
(3) Press the "POWER" button on the unit to turn off the unit.
(4) Press the "PLAY" button on the unit for over 5 seconds
while the unit is turned off. The code currently set appears
on the front display panel.
(5) Press the "STOP" button on the remote control to change
the unit’s code. When FDP indicator displays "DVD1," it
means that the Remote Control Code has been changed to
"1."
2.3.2 Setting the Jig RCU mode
(1) Turn on the power.
(2) Press the "DV/HDD/DVD" select button repeatedly on the
unit so that the DVD lamp lights up on the unit.
(3) Press the following remocon keys continuously within 2
seconds " SET UP "
→
" 2 "
→
" 8 "
→
" ENTER ".
When the unit is set to the Jig RCU mode, the symbols
( " : " ) in the time display of the FDP are blinked.
(Refer to Fig.2-3a User/Jig RCU mode)
2.3.3 Setting the User RCU mode
(1) Turn off the power.
(2) Press the "REC" and "PAUSE" buttons of the unit simulta-
neously. Alternatively, transmit the code "43-9D" from the
Jig RCU.
( blinked)
Jig RCU mode
User RCU mode