background image

3

1. Check of Accessories / Bundled Items

(1) Instruction Manual

(This booklet) .............................. X1

(2) Warranty Card ............................ X1
(3) AC Adaptor

(Cord Length: Approx. 1.8m) ...... X1

Accessories/bundled items included with the network decoder are listed as follows. Check if

there is any shortage and contact the sales outlet at which the purchase is made if neces-

sary.

(4) AC Cord (Approx. 1.8m) ................ X1
(5) Remote Controller ......................... X1
(6) Batteries (UM-3 AA) ...................... X2
(7) Cord Clamp ................................... X1

Summary of Contents for DM-ND300E

Page 1: ... Manual LST0166 001B DM ND300E MPEG 2 Network Decoder MPEG 2 NETWORK DECODER LST0166 001B POWER ACT PLAY REQ ERR DM ND300E MPEG 2 NETWORK DECODER LINK 100M FDX TX RX COL This instruction book is made from 100 recycled paper ...

Page 2: ...ot place heavy objects on the unit like a monitor on TV Please keep the mobile rack into the com partment As injury may result from fin gers getting clamped Please do not block the ventilation open ings Avoid violent shocks to the unit Do not drop the unit Please remove the AC adapter to save energy when the unit is not in use 䡵 Maintaining the unit Please turn off the power before performing main...

Page 3: ...l identifications of our plug connect as follows Blue wire to terminal coded N Neutral or coloured Black Brown wire to terminal coded L Live or coloured Red If in doubt consult a competent electri cian POWER SYSTEM Connection to the mains supply This unit operates on voltage of 220 V to 240 V AC 50 Hz 60 Hz WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN O...

Page 4: ...meiden Decken Sie niemals die Lüftungs öffnungen ab Setzen Sie das Gerät keinerlei Er schütterungen und Schlägen aus und lassen Sie es nicht fallen Trennen Sie den Netzadapter vom Netz wenn Sie das Gerät nicht benutzen Sie sparen auf diese Weise Energie 䡵 Reinigung Schalten Sie das Gerät unbedingt ab bevor Sie die Reinigung durchführen Wischen Sie das Gerät mit einem weichen Tuch ab Verwenden Sie ...

Page 5: ...Steckverbinders ange schlossen werden der entweder mit dem Buchstaben N markiert oder SCHWARZ farbkodiert ist Der BRAUN markierte Leiter muss an den Kontakt des Steckverbinders angeschlossen werden der entweder mit dem Buchstaben L markiert oder ROT farbkodiert ist 4 VERSORGUNG Anschluss an das Stromnetz Das Gerät wird mit einer Netzs pannung von 220 V bis 240 V AC 50 Hz 60 Hz betrieben WARNUNG SE...

Page 6: ...5 AC Eingang 220 V bis 240 V AC 50 Hz 60 Hz DC Ausgang 9 V DC 1 66 A Abmessungen 90 58 28 mm Gewicht 180 AC Kabel ca 1 80 m abnehmbar DC Kabel ca 1 80 m AC Netzteil TECHNISCHE DATEN ...

Page 7: ...Kabel Länge VIDEO OUT 1 KOAXIALKABEL GESCHIRMT 10 Meter VIDEO OUT 2 S KABEL GESCHIRMT 10 Meter AUDIO OUT LEFT CINCHKABEL RCA GESCHIRMT 10 Meter AUDIO OUT RIGHT CINCHKABEL RCA GESCHIRMT 10 Meter DV 9V NETZTEILKABEL UNGESCHIRMT 1 8 Meter LAN CAT5 STP KABEL 100 Meter COM D SUB KABEL 9 POLIG GESCHIRMT 10 Meter AC IN AC NETZTEIL AC NETZKABEL 2 POLIG 1 8 Meter Der Einschaltstrom dieses Geräts beträgt 16...

Page 8: ...trol and transport are RTSP and RTP compliant Receives and decompresses MPEG 2 stream up to a maximum of 10Mbps and outputs analog composite signal YC signal as well as analog audio signals Compact and lightweight Contents 1 Check of Accessories Bundled Items 3 2 Names and Functions 4 3 How To Operate 8 4 Specifications 9 5 Caution for Cables 10 6 Saving Energy 11 7 Others 11 ...

Page 9: ...ptor Cord Length Approx 1 8m X1 Accessories bundled items included with the network decoder are listed as follows Check if there is any shortage and contact the sales outlet at which the purchase is made if neces sary 4 AC Cord Approx 1 8m X1 5 Remote Controller X1 6 Batteries UM 3 AA X2 7 Cord Clamp X1 ...

Page 10: ...ction speed of network Light On 100 Mbps Light Off 10 Mbps 8 FDX LED Green Displays the duplex mode of network Light On Full duplex Light Off Half du plex 9 TX LED Orange Lights up when packets are transmitted from the Ethernet 0 RX LED Orange Lights up when packets are received from the Ethernet including packets to other destinations COL LED Red Lights up when collision occurs on the Ethernet Re...

Page 11: ... cases of emergency to reset equipment 9 DC 9 V Connect to the AC adaptor supplied with this equipment Do not use any AC adap tors other than the one supplied 0 DC Cord Fastening Hook Fasten the DC cord using the cord clamp supplied Fastening of cord shall be per formed by the sales outlet at which this equipment is purchased PRECAUTION It is recommended that the equipment be earthed through the D...

Page 12: ...ion as HOME button 3 Number Buttons To play back the network encoder that has been pre assigned and are invalid buttons 4 7 Not used 8 OK Button To play back the network encoder last used for playing back Same functions as Play Back Button To play back the network encoder last used for playing back Not activated until playing back has been performed using the HOME or Number button 1 2 3 4 5 7 0 6 ...

Page 13: ...as withilluminationthatisstrongerthanthelight emission of the remote controller or where inverted fluorescent lights are used 3 When system makes use of a menu server The menu screen is displayed by the re mote control and selection of network en coder is possible A separate HTML server is required when using this sys tem Please refer to the sales outlet at which this equipment is purchased for mo...

Page 14: ...the Stop button on the remote controller to stop playing back the video sound When system makes use of a menu server In the case of a system that uses menus the menu screen is displayed by pressing HOME button on the remote controller Select the menu using the arrow keys on the remote controller followed by pressing OK to play back video audio from the network encoder Press the Pause button on the...

Page 15: ...nput format MPEG 2 Transport Stream ISO IEC13818 1 TS packet size 188 byte Serial RS 232C D sub9Pin male x 1 Power supply External AC adaptor DC9 V 1 66 A Current consumption DC 9 V 0 6 A as indicated on main unit Operating environment 5 C 35 C Non dew condensation External dimensions W 163 x D 164 x H 24 mm Weight AC input AC 220 V 240 V 50 Hz 60 Hz DC output DC9 V 1 66 A Dimensions 90 mm X 58 mm...

Page 16: ...ing lengths Port Cable Length VIDEO OUT 1 SHIELDED COAXIAL CABLE 10 meters VIDEO OUT 2 SHIELDED S CABLE 10 meters AUDIO OUT LEFT SHIELDED RCA PIN CABLE 10 meters AUDIO OUT RIGHT SHIELDED RCA PIN CABLE 10 meters DV 9V UNSHIELDED CABLE FROM AC ADAPTER 1 8 meters LAN CATEGORY 5 TWIST PAIR SHIELDED CABLE 100 meters COM SHIELDED 9PIN D SUB CABLE 10 meters AC IN AC ADAPTER 2 PIN AC POWER CABLE 1 8 meter...

Page 17: ...e altered without any prior notice 3 Our company shall not be responsible for any eventualities arising from the operation of this equipment 4 Diagrams are enlarged omitted or composited to ease explanation and may slightly differ from the actual item 6 Saving Energy Turn off the power when not in use to save energy ...

Page 18: ...12 REMOTE COM LAN AUDIO RESET VIDEO OUT2 VIDEO OUT1 RIGHT LEFT DC9V DM ND300E MPEG 2 NETWORK DECODER 100M COL RX TX FDX LINK ERR REQ PLAY ACT POWER 164 8 163 24 3 Dimension Unit mm ...

Page 19: ...13 ...

Page 20: ...oder MPEG LST0166 001B VICTOR COMPANY OF JAPAN LIMITED is a registered trademark owned by VICTOR COMPANY OF JAPAN LTD is a registered trademark in Japan the U S A the U K and many other countries 2003 VICTOR COMPANY OF JAPAN LIMITED ...

Reviews: