49
ENGLISH
Getting Started
Preparation
Basic
Operation
S
ettings
Troubleshooting
Othe
rs
Reference command
Type
Command
Description
Power (On)
PC
This unit: 3F 89 01 50 57 0A
This unit
PC: 06 89 01 50 57 0A
This unit
PC: 40 89 01 50 57 31 0A
When information on power-on mode is
acquired
Input (S-VIDEO)
PC
This unit: 3F 89 01 49 50 0A
This unit
PC: 06 89 01 49 50 0A
This unit
PC: 40 89 01 49 50 30 0A
When information on S-VIDEO input is
acquired
Gamma table
(Custom)
PC
This unit: 3F 89 01 47 54 0A
This unit
PC: 06 89 01 47 54 0A
This unit
PC: 40 89 01 47 54 34 0A
When information on “Custom” is acquired
Gamma coefficient
(1.8)
PC
This unit: 3F 89 01 47 50 0A
This unit
PC: 06 89 01 47 50 0A
This unit
PC: 40 89 01 47 50 30 0A
When information on “1.8” is acquired
Gamma data
(R)
PC
This unit: 3F 89 01 47 52 0A
This unit
PC: 06 89 01 47 52 0A
This unit
PC: 512 bytes of gamma data
When information on red gamma data is
acquired
Test pattern
(Staircase)
PC
This unit: 3F 89 01 54 53 0A
This unit
PC: 06 89 01 54 53 0A
This unit
PC: 40 89 01 54 53 36 0A
When information on staircase (gray) is
acquired