9
5
Calibration in progress.
While calibration is in progress, make sure that the surrounding
light does not fluctuate.
Otherwise, it may affect the calibration results.
* Noise may appear on the screen when data writing is in
progress.
6
The results for each Calibration Type are displayed.
Gamma
Calibration results are shown in a white line.
The state before calibration is performed is shown in a blue line.
The green line represents Gamma 2.2.
Color
Calibration results are shown in a white line.
The state before calibration is performed is shown in a blue line.
The pink line indicates the color gamut of Rec. 709.
The chromaticity of each color is indicated using x-y coordinates.
* The Profile Name being created and saved won’t be displayed
when Custom 1 to 4 is selected, but shown as Custom 1 to 4
instead.
Color Temp
The chromaticity of the color temperature for each gray level is
indicated by
●
of the respective gray levels.
The red circle indicates the intended chromaticity xy ± 0.01.
7
Save the results if these are in order.
Click the “SAVE” button.
After saving is complete, below message is displayed.
Click “OK” (to return to the top menu).
To exit without saving the result, click
(to return to the top
menu).
Caution
The calibration result includes the characteristics of the screen.
It is recommended to set the Screen Adjust function of the projector to off after calibration.
Gamma
Color
Color Temp
Click