Remote Control Timing Definitions: 

 
13.3.1   

The modulated carrier is derived from a 432KHx clock and is 1/12 of the 
 frequency with a 1/3 duty cycle. 
 

13.3.2

 

  

When data is transmitted repeatedly, the frame cycle is 113.7mS or  256T 
 periods. 

 
13.3.3

 

  

A frame consists of a two-bit sync code, a one-bit toggling control code, a 
five-bit system code (address) and a six-bit data code. 

 
 
                     1 Frame 
 
 
 
                             256T                256T                256T               256T 
 
1 Frame: 
 

 

S0  S1 TG C0 C1 C2 C3 C4 D0 D1 D2 D3 D4 
 
 
S0, S1 = Sync (2 bit) 
      TG = Toggle (1 bit) 
C0-C4 = Custom address code (1 bit, see below) 
D0-D4 = Data code (5 bit, see table below) 
 
 
 
Data item 

Time (sec.) 

Time (no. of period) 

Data off time 

0.888mS 

2T 

Data on time 

0.888mS 

2T 

Data period (0) 

3.552mS 

4T 

Data period (1) 

3.552mS 

4T 

Frame output cycle 

113.7mS 

256T 

 
 
 
 
 

Summary of Contents for DLA-HD2KU - D-ila Projector Head

Page 1: ...e Material ABS plastic 13 1 4 LED Yes Red 13 1 5 IR Emitter 1 13 1 6 Range 20 30ft 6 9m 13 1 7 Power Supply 2 x AAA Batteries 13 1 8 Power Consumption Appox 50mA at IR transmit 13 1 10 Operation Temp 5 C to 40 C 13 1 11 Storage Temp 40 C to 70 C 13 1 12 Humidity Range 10 to 90 non condensing 13 1 14 Infrared Frequency 38 KHz Figure 3 ...

Page 2: ...b Button direct access to select the YPrPb input 13 2 8 DVD Direct access to select the DVD input mode when used with the DVP1510 or other Faroudja processor with an internal DVD transport 13 2 9 Pass TX Selects the pass through input If pressed twice the input will switch to the pass through transcoding input Direct access to pass through input is also granted by pressing the PASS TX key followed...

Page 3: ...settings to a user profile When in setup mode the store key is used to verify and store the newly selected scan rate 13 2 17 0 9 Buttons Used to enter values when using the direct access levels for the picture controls 13 2 18 Brightness Button Used to raise and lower the picture brightness level 13 2 19 Contrast Button Used to raise and lower the picture contrast level 13 2 20 Color Button Used t...

Page 4: ...mS or 256T periods 13 3 3 A frame consists of a two bit sync code a one bit toggling control code a five bit system code address and a six bit data code 1 Frame 256T 256T 256T 256T 1 Frame S0 S1 TG C0 C1 C2 C3 C4 D0 D1 D2 D3 D4 S0 S1 Sync 2 bit TG Toggle 1 bit C0 C4 Custom address code 1 bit see below D0 D4 Data code 5 bit see table below Data item Time sec Time no of period Data off time 0 888mS ...

Page 5: ...4 3 9 09 0 0 1 0 0 1 Letterbox 10 0a 0 0 1 0 1 0 Anamorphic 11 0b 0 0 1 0 1 1 Brightness 12 0c 0 0 1 1 0 0 Contrast 13 0d 0 0 1 1 0 1 Color 14 0e 0 0 1 1 1 0 Tint 15 0f 0 0 1 1 1 1 Detail 16 10 0 1 0 0 0 0 Menu 17 11 0 1 0 0 0 1 Preset 18 12 0 1 0 0 1 0 Store 19 13 0 1 0 0 1 1 Function Up 20 14 0 1 0 1 0 0 Function Down 21 15 0 1 0 1 0 1 Value Up 22 16 0 1 0 1 1 0 Value Down 23 17 0 1 0 1 1 1 0 24...

Reviews: