background image

16

Recorder

BR-DV600

BR-DV600

BR-S800

SR-S365 (U MODEL)
SR-S388 (E MODEL)

BR-DV600

Player

BR-DV600

BR-DV600

BR-DV600

BR-DV600

BR-S800/BR-S500 (+ SA-N50)*

5

Edit adjust setting

The No. 353 <EDIT ADJUST> menu switch must be adjusted according to the configuration of the editing system being
used.

Setting table (when the RM-G800 is used)

Signal connection method

Analog

IEEE 1394

Analog

Analog

Analog

Setting

0 F

0 F

0 F

0 F

---

Setting

4 F

2 F

---

---

3 F

3  CONNECTIONS

DC 12V

PGZ01945

TIMER

TIME CODE

SPARE

COMPONENT

VIDEO

SYNC IN

REC

OFF

PLAY

DV 

IN/OUT

REMOTE

AUDIO

2

1

SERIAL

CH 1/3

OUT

OUT

IN

IN

B-Y

IN

Y/C

LINE

OUT

OUT

MONITOR

CH 2/4

MONITOR

OUT

R-Y

Y

Video signal

Audio signal

Non-linear editing system

Remote control

5

Non-linear editing system

Material recorded on a MiniDV tape can be captured to a non-linear editing system. The following non-linear editing
systems are able to utilize Super Scene Finder (SSF) data.
• Canopus Corporation: DV Rex RT
• Casablanca

5

Control via the DV connector

• When the DV connector is used for control, assemble editing cannot be performed.
• When the VCR is stopped via the DV connector, a command error message may be returned to the controller.  This is not

a malfunction.

Notes on connecting a cable to the [DV IN/OUT] connector

Set the following menu switches, turn the connected equipment ON and then connect the cable to the [DV
IN/OUT] connector.  (If two BR-DV600s are connected to each other, it is not necessary to turn them ON.)

Menu switch settings
• When used as a player
     Set the No. 108 <VIDEO INPUT SELECT> menu switch to any position except “IEEE 1394”.
     (If this switch is currently set to “IEEE 1394”, change the setting and turn the power OFF and ON again.)
• When used as a recorder
    Set the No. 108 <VIDEO INPUT SELECT> menu switch to “IEEE 1394”.
• When controlled by another device via the [DV INPUT] connector
    Set the No. 050 <REMOTE SELECT> menu switch to “IEEE 1394”.

* To ensure the stability of input signals, install the SA-N50 in the BR-DV600.

17

4  MENU SWITCHES

You can set menu switches using either the on-screen display or the counter display.  To set switches on the on-screen display,
you will need to connect a monitor to the VCR’s [VIDEO MONITOR OUT] connector.  This section explains how to set switches
using the on-screen display.  The same procedures apply to switch setting on the counter display, the only difference being that
each menu switch item is indicated by numeric code rather than by name.

Menu switch group
select screen

0 3 : SYNC SE L ECT

5 0 : REMOTE SE L ECT

0

0

OF F

0 2 : OPERAT I ON LOCK

0

STOP

TCR 1 2 : 0 0 : 0 0 : 0 0

0 0

~

:

SYSTEM

0 0

~

:

T I ME CODE

0 0

~

: ONSCREEN

M

:

HOUR METER

3
4
5
H

0 0

~

:

AUD I O

2

0 0

~

:

SERVO / SYSTEM

0

0 0

~

:

V I DEO

1

[SELECT]

[MENU]

[SET]

[MENU]

[SHIFT]

U

A

US +RS 4 2

TO

2 A

J VC   B

4-1  Menu switch organization

Menu switch group select screen

Pressing the [MENU] button with the normal screen
displayed brings up the menu switch group select screen.
Select the desired group with the [SHIFT +/–] button.
The selected group number blinks.
Press the [SELECT] button to go to the selected group
menu switch setting screen.

Menu switch setting screen

To access this screen, press the [SELECT] button on the
menu switch group select screen.
Press the [MENU] button to go to the menu switch group
select screen.

Menu switch group select screen

Menu switch setting screen

On-screen display

L I NE

0 8 : V I DEO I NPUT SE L ECT

1

0 3 : SYNC SE L ECT

U

A

5 0 : REMOTE SE L ECT

US +RS 4 2

0

0

OF F

0 2 : OPERAT I ON LOCK

0

TO

2 A

J VC   B

STOP

TCR 1 2 : 0 0 : 0 0 : 0 0

( HOUR METER )

H

: DRUM HOUR METER

0 0 0 0 0

D

0H

0 0

:

SYSTEM

0 0

:

T I ME CODE

0 0

: ONSCREEN

M

:

HOUR METER

3
4
5
H

0 0

:

AUD I O

2

0 0

:

SERVO / SYSTEM

0

0 0

:

V I DEO

1

[SET]

[MENU]

[SHIFT]

[SELECT]

[MENU]

Menu switch setting screen

On-screen display

Switching the
setting screen

[SHIFT] +/–: Item select

SELECT: Changes the setting.
SET:

Enters the setting.

Menu switch display

SHIFT

SET

SELECT

SHIFT

MENU

HOLD

AUDIO

MONITOR OUTPUT COUNTER

SHIFT

A. DUB

ADVANCE PRESET

L

CTL

TC
UB

CH-1/2

CH-3/4

R

MIX

MIX

MENU

OVER

OVER

H

M

S

F

AUD LOCK

32k

48k

PB

NDF

SERVO RF

DEW

AUTO OFF

HOLD

CH 2/4

CH 1/3

dB

40 30

20

10

0

D A T A     S E T

A B O R T

Counter display

When entered

When data has not
been entered yet

Menu switch setting procedure

1

Press the [SHIFT –/+] button on the menu switch set-
ting screen to select the menu switch you want to set.

[

The selected menu switch number blinks.

2

Press the [SELECT] button to change the set value.

3

Repeat steps 

1

 and 

2

 to change any other menu switches.

4

Press the [SET] button to end menu switch setting.

[

The set value is entered and the normal screen is

restored. When entering the data, the indications shown
on the left are displayed.  If data has not been entered
and menu switch setting is ended, “Abort” indication is
shown.

To access another group menu switch setting screen without
ending menu switch setting, press the [MENU] button.

For servicing
See the service manual page 1-10 “1.6 SERVICE MENU”.

Summary of Contents for BR-DV600E - Professional Dv Recorder/player

Page 1: ...CT SHIFT MENU HOLD AUDIO MONITOR OUTPUT COUNTER SHIFT A DUB ADVANCE PRESET L CTL TC UB CH 1 2 CH 3 4 R MIX MIX REW STOP FF REC PLAY PAUSE ON OFF VIDEO CASSETTE RECORDER BR DV600U U INSTRUCTIONS VIDEO CASSETTE RECORDER BR DV600E SL96180 Thank you for purchasing this JVC product Before operating this unit please read the instructions carefully to ensure the best possible performance R This instructi...

Page 2: ...iance yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 17 Unplug this appliance from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power cord or plug is damaged or frayed b If liquid has been spilled into the appliance c If the appliance has b...

Page 3: ...duit Cette tension est suffisante pour provoquer l électrocution de personnes Le point d exclamation à l intérieur d un triangle équilatéral est destiné à alerter l utilisateur sur la présence d opérations d entretien importantes au sujet desquelles des renseignements se trouvent dans le manuel d instructions Ces symboles ne sont utilisés qu aux Etats Unis The lightning flash with arrowhead symbol...

Page 4: ...220 240 V DC 12 V E MODEL 5 Audio dubbing function 32 kHz sampling rate 5 Compact lightweight design 5 SMPTE time code recording and playback U MODEL EBU time code recording and playback E MODEL 5 Sampling rate converter for 32 kHz 12 bit or 48 kHz 16 bit digital audio 5 External timer start function 5 External sync signal input connectors 1 2 Maintenance Maintenance consultation Consult your loca...

Page 5: ...PHONES MIC REMOTE LOCAL EJECT OPERATE REC LEVEL CH 2 4 CH 1 3 SHIFT SET SELECT SHIFT MENU HOLD AUDIO MONITOR OUTPUT COUNTER SHIFT A DUB ADVANCE PRESET L CTL TC UB CH 1 2 CH 3 4 R MIX MIX REW STOP FF REC PLAY PAUSE ON OFF MENU OVER OVER H M S F AUD LOCK SP 32k 48k SLAVE PB NDF SERVO RF DEW AUTO OFF HOLD CH 2 4 CH 1 3 VIDEO CASSETTE RECORDER BR DV600U dB 40 30 20 10 0 1 2 3 4 5 6 7 8 9 0 1 OPERATE s...

Page 6: ...t a wired remote control such as the RM G30 to control this unit 6 SPARE connector This connector is empty and has no function 7 TIMER switch Use to select the timer operation REC Timer recording OFF Timer function OFF PLAY Timer playback See EXTERNAL TIMER START FUNCTION on page 26 8 TIME CODE OUT connector Use to output time code signals 9 SYNC IN connector Input reference sync signals See Refer...

Page 7: ...y appear in the playback picture This is not a malfunction Notes 10 2 4 LCD Display 2 CONTROLS CONNECTORS AND DISPLAYS 1 Counter display section Three types of indications can be displayed in the counter display section 1 Tape counter Normally the indication selected with the COUN TER switch is shown When the No 516 DISPLAY SELECT menu switch is set to CLOCK the time and date are shown See Built i...

Page 8: ...elect for 4 channel audio The selected audio channel is shown in the table below 5 Digital outputs Digital signals conforming to IEEE 1394 are output from the DV IN OUT connector Relationship between AUDIO OUTPUT AUDIO MONITOR switch and audio output channel During playback with 32 kHz sampling audio dubbing and DV input with the 32 kHz sampling in the EE mode Regardless of setting of this switch ...

Page 9: ...editing Use the RM G800 with the Auto EE mode OFF Otherwise the IEEE 1394 EE inh error indication is shown For servicing See the service manual page 1 20 1 11 EDITING SYSTEM USING THE BR DV600 15 3 CONNECTIONS 3 4 Editing system examples 5 Mixed S VHS VHS system This is an editing system which uses the BR DV600U as a feeder player with an RS 422A serial remote controller such as the RM G820 In thi...

Page 10: ... display the only difference being that each menu switch item is indicated by numeric code rather than by name Menu switch group select screen 0 3 SYNC SELECT 5 0 REMOTE SELECT 0 0 OFF 0 2 OPERAT I ON LOCK 0 STOP TCR 1 2 0 0 0 0 0 0 0 0 SYSTEM 0 0 T I ME CODE 0 0 ONSCREEN M HOUR METER 3 4 5 H 0 0 AUD I O 2 0 0 SERVO SYSTEM 0 0 0 V I DEO 1 SELECT MENU SET MENU SHIFT U A US RS4 2 TO 2A JVC B 4 1 Men...

Page 11: ...e recorded on the GY DV500 Notes This setting affects recording and playback of analog video signals Picture hue and brightness can be affected if dubbing is repeated without applying a setup suitable to video signals For servicing See the service manual page 1 19 1 11 SET UP SW 19 4 MENU SWITCHES 4 2 Menu switch details q Factory setting 00 The number in the bracket shows the set value on the cou...

Page 12: ...Setting qPRESET 00 Engages the Preset mode REGEN 01 Engages the Regen mode 415 TCG MODE Details Selects the time code generator Run mode Setting FREE RUN 00 Engages the Free Run mode qREC RUN 01 Engages the Rec Run mode 416 NON DROP DROP U MODEL Details Selects the time code generator Drop Frame mode Setting qDROP 00 Engages the Drop Frame mode NON DROP 01 Engages the Non Drop Frame mode 500 ON SC...

Page 13: ...HIFT SET SELECT SHIFT MENU HOLD AUDIO MONITOR OUTPUT COUNTER SHIFT A DUB ADVANCE PRESET L CTL TC UB CH 1 2 CH 3 4 R MIX MIX REW STOP FF REC PLAY PAUSE ON OFF MENU OVER OVER H M S F AUD LOCK SP 32k 48k SLAVE PB NDF SERVO RF DEW AUTO OFF HOLD CH 2 4 CH 1 3 VIDEO CASSETTE RECORDER BR DV600U dB 40 30 20 10 0 6 RECORDING Recording preparation Loading a cassette Check that the erasure prevention tab is ...

Page 14: ... date time As shown in the diagram the audio recording section provides 2 channels or 4 channels depending on the sampling rate frequency selected In the Audio Dubbing mode audio signals are recorded in the CH3 and CH4 section which is created when the 32 kHz sampling fre quency is selected Audio area Video area Sub code area 25 PHONES MIC REMOTE LOCAL EJECT OPERATE REC LEVEL CH 2 4 CH 1 3 SHIFT S...

Page 15: ... 9 TIME CODE The time code is recorded frame by frame together with the materials to be recorded on the tape With this time code the position of the materials can be precisely specified improving the editing accuracy and working efficiency The editing accuracy of 0 frame may not be obtained even though the time code is used depending on the performance of the VCR and editing controller and influen...

Page 16: ...ECT REGEN No 415 TCG MODE REC RUN or FREE RUN No 416 NON DROP DROP NON DROP or DROP U MODEL Operation 1Start recording While pressing the REC button press the PLAY button The time code and user bits are recorded following the data recorded on the tape The time code data is shown on the on screen display and counter display On the on screen display the counter mode is shown as TCR or UBR To stop re...

Page 17: ...on software for Canopus s DVRex RT is distributed at no charge on the Internet as of February 2000 pSearch Reading out SSF data 1Insert the tape on which SSF data is recorded 2Transmit the RS 232C command D5h SSF DATA SENSE from a personal computer or a non linear editing system The SSF data is returned from the VCR Display example START ID REEL NO SCENE MARK IN MARK OUT CUE 001 M 00 00 00 16 00 0...

Page 18: ...C REV X0 2 0 2x reverse play 4D R STILL Pause 4E REV X10 10x reverse play 4F STILL Pause 7B OPERATE ON Operating mode ON 7C OPERATE OFF Operating mode OFF A0 STANDBY ON Standby ON A1 STANDBY OFF Standby OFF A2 PREROLL Preroll A3 EJECT Eject cassette AB FF Fast forward When this command is transmitted during playback playback speed changes to 10x AC REW Rewind When this command is transmitted durin...

Page 19: ...ata D6 PREROLL TIME SENSE Use to check the preroll time 2 byte data is returned showing the seconds tens place and ones place D7 STATUS SENSE Use to check the status Refer to the contents of the STATUS SENSE D8 CURRENT TC SENSE Use to check the time code data The data is returned in the order of hour minute second and frame D9 CURRENT CTL SENSE Use to check the CTL data The uppermost digit shows p...

Page 20: ...o available Command Description 02 ERROR Returned when the VCR receives an invalid command after the second byte of the transmitted command In this case even though commands are sent continuously no commands can be accepted except STATUS SENSE To release this error mode send the following commands 41 CLEAR ERROR Clears the last transmitted byte Use this to release the error mode as well 56 CLEAR A...

Page 21: ... 0 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 0 1 1 0 7 0 1 1 1 8 1 0 0 0 9 1 0 0 1 10 1 0 1 0 11 1 0 1 1 504 82 D2 TIME 0 0 MODE TIME 0 1 505 82 D2 OFF 0 ON 1 514 83 D2 DATE 0 0 0 CLOCK 0 0 1 DATE CLOCK 0 1 0 TC 0 1 1 516 83 D2 TC 0 CLOCK 1 11 RS 232C INTERFACE DATA0 D1 D2 Set value Corresponding bit values Menu switch No 7 6 5 4 3 2 1 0 002 01 D1 OFF 0 ON 1 003 01 D2 INTERNAL 0 0 EXTERNAL 0 1 VIDEO 1 0 AUT...

Page 22: ...erations are possible Operation continues Operation stops Operation stops Operation stops Operation continues Operation stops Operation continues Operation stops about 60 seconds after the fan motor stops with the No 397 FAN STOP SHUTDOWN menu switch set to ENABLE The operation continues 12 TROUBLESHOOTING Turn the power on again In some cases the tape may be damaged so use a different tape If the...

Page 23: ...E 1394 Connectors 5 RS 422 interface D sub 9 pin 5 JVC bus connector DIN 12 pin Accessory AC cable x 1 Option SA K46U RS 232C interface board Design and specifications subject to change without notice Dimensions unit mm General 5 Power requirements AC 120 V U MODEL AC 220 240 V E MODEL 50 60 Hz DC 12 V 10 5 V to 17 V 5 Power consumption 27 W U MODEL 250 mA E MODEL 5 Dimensions W 212 mm x H 88 mm x...

Page 24: ...weimal des Reinigungsbandes alle 5 Stunden alle 20 bis 30 Stunden alle 5 Stunden Hinweis 1 Bei Verwendung in einer Umgebung mit niedriger Luftfeuchtigkeit 10 bis 30 relativ sollte Kopfreinigung doppelt so oft wie im obigen Diagramm angegeben durchgeführt werden Hinweis 2 Wenn direkt nach dem Kopfreinigen ein ME80 Band verwendet wird so bleibt die Warnanzeige für den Videorekorder Kopf möglicherwei...