background image

20

5

External dimensions (unit: mm)

482

465

2

195

176.5

362

195

195

7

43

5.5

16

16

50

45

23.1

32

152.4

139.7

123.8

23

489

LOCAL

ENTER

MENU

ESC

POWER

STATUS INPUT SYNC

REMOTE

BC-D2300U HDTV UP CONVERTER

430

±

3

POWER

AC IN

ALARM

REMOTE-IN

REMOTE-OUT

TERMINATE

OFF

ON

LOOP

THROUGH

IN

OUT

SDI

1

2

3

HD SERIAL OUT

REF

Pb

Y

Pr

CVBS

CN1

ON

OFF

FUSE

1.6A(125V)

FUSE

9

6

5

1

9

6

5

1

9

6

5

1

Design and specifications subject to change without notice.

Specifications (contd.)

OTHERS

21

Supplement

Put L-metal supports on the both sides of EIA rack
to secure strength.

 

Attaching the L-metal support on EIA  rack

EIA rack

L-metal support 

L-metal support 

Screw

Min.420

Min.

70

45

Thickness: 2 mm

L-metal support

Rack mounting is optional. Use only with racks that have fully adjustable vertical rack rails.

Use the rack mount brackets (eras) and L-metal supports together.
Do not use only the rack mount brackets (ears) by themselves for support.

WARNING :

Summary of Contents for BC-D2300U

Page 1: ...IONS HDTV UPCONVERTER BC D2300U SS961574 002 R POWER LOCAL REMOTE STATUS INPUT SYNC MENU ENTER ESC BC D2300U HDTV UP CONVERTER For Customer Use Enter below the Serial No which is located on the top cover Retain this information for future reference Model No BC D2300U Serial No Thank you for purchasing this JVC product Before operating this unit please read the instructions carefully to ensure the ...

Page 2: ...justment of other controls may result in damage and will often require extensive work by a qualified technician to restore the appliance to normal operation e If the appliance has been dropped or the cabinet has been damaged f When the appliance exhibits a distinct change in performance this indicates a need for service 18 When replacement parts are required be sure the service technician has used...

Page 3: ...ne or thinner as these may deform or discolor the cabinet surface To remove excessive dirt clean the unit with a mild detergent diluted with water then wipe it with dry cloth Do not use the unit in an environment exposed to gases generated by chemicals or organic solvents INSTALLATION IN A RACK This unit can be installed in EIA standard rack Ensure sufficient rack strength by attaching L metal sup...

Page 4: ...emote control this unit set the LOCAL REMOTE switch on the front panel to REMOTE REMOTE OUT connector D sub 9 pin female Outputs the control signals input to the REMOTE IN connector or 0 ALARM connector as signals conform ing to the RS 485 serial interface Connect this connec tor to the REMOTE IN connector of another device Up to 31 devices can be connected in series with this connection TERMINATE...

Page 5: ... selected settings are recalled When completed the completion display is shown Memorandum When the check screen is shown press the ESC button to cancel it The previous Profile Load menu setting display is restored 6Press the ENTER MENU button or ESC button Menu setting display is restored and the recalled menu settings are activated 7Press the ESC button to restore the normal display Memorandum Th...

Page 6: ...ntents contd The items in the shaded area are shown when the optional software is installed Factory Setting Items V Position Motion Sense Enhance Level Variable Enhancer Enhance Level Enhance Freq Cut Off Freq Threshold Noise Reduction Settings 63 0 63 0 8 15 5 0 15 OFF ON 5 0 15 2 4 5 3 7 0 15 OFF ON Contents Adjusts the picture s vertical position varies in 63 lines Note When Output Mode is set ...

Page 7: ...re will be monochrome if the Back Color L is set to 0 black or 100 white This item is shown only when the Back Color Mode is set to HSL Sets the background color hue In most cases the following colors can be obtained 0 Red 120 Green 240 Blue This item is shown only when the Back Color Mode is set to HSL 13 Items Color Correction White Level Black Level White Color B White Color R Back Color B Back...

Page 8: ...ry Setting Items Administration Remote ID Remote Speed Remote Port Active Line Alarm Name Version Serial No License key Running Time Settings 1 31 9600 19200 38400 REMOTE IN ALARM 480 486 OFF ON BC D2300 Contents Press the ENTER MENU button to enter the administration sub menu The following nine items can be set on the administration sub menu Sets the remote ID of this unit to remote control this ...

Page 9: ...EF Pb Y Pr CVBS CN1 ON OFF FUSE 1 6A 125V FUSE 9 6 5 1 9 6 5 1 9 6 5 1 ALARM 1 5 9 6 Pin Name Contents number 1 NC Unconnected 2 RD Reception data for maintenance 3 SD Transmission data for maintenance 4 ALARM2 B Alarm output 2 B terminal 5 GND Signal ground 6 ALARM2 A Alarm output 2 A terminal 7 ALARM1 A Alarm output 1 A terminal 8 ALARM1 B Alarm output 1 B terminal 9 NC Unconnected Front panel E...

Page 10: ...gnal SMPTE259M 1 line 0 8 Vp p 75 ohms unbalanced active through Bit rate 270 Mbps Embedded audio signal 4 ch sampling frequency of 48 kHz Sync signals Sync signal 75 ohms unbalanced loop through 1 line B B 0 45 Vp p NTSC HD SYNC Positive and negative bipolarity tri sync signal of 600 mVp p 300 mVp p 5Output signal Video and audio HD digital serial signal SMPTE292M 3 lines 0 8 Vp p 75 ohms unbalan...

Page 11: ...1 9 6 5 1 9 6 5 1 Design and specifications subject to change without notice Specifications contd OTHERS 21 Supplement Put L metal supports on the both sides of EIA rack to secure strength Attaching the L metal support on EIA rack EIA rack L metal support L metal support Screw Min 420 Min 70 45 Thickness 2 mm L metal support Rack mounting is optional Use only with racks that have fully adjustable ...

Page 12: ...22 MEMO 23 MEMO ...

Reviews: