Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment of
CORNER
UP/ LOW
Signal
generator
Remote
control unit
7.COR-PIN
8.COR-UP
9.COR-LO
31. Select 9.COR-LO with the FUNCTION UP/DOWN key.
32. Set the initial setting value of COR-LO with the FUNCTION
LEFT/RIGHT key.
33. Adjust COR-LO, and bring the lines at the low corner straight.
34. Select 8.COR-UP with the FUNCTION UP/DOWN key.
35. Set the initial setting value of COR-UP with the FUNCTION
LEFT/RIGHT key.
36. Adjust COR-UP, and bring the lines at the upper corner
straight.
37. If the extreme upper & lower corners have pin or barrel
condition a little chose 7.COR-PIN and adjust it to get the
straight.
38. Press the MENU key and memorize the set value.
Adjustment of
ANGLE
Signal
generator
Remote
control unit
10.ANGLE
"
In case which there is a parallelogram distortion of images on
the screen.
39. Select 10.ANGLE with the FUNCTION UP/DOWN key.
40. Adjust ANGLE, and bring the vertical lines straight.
41. Press the MENU key and memorize the set value.
Adjustment
of BOW
Signal
generator
Remote
control unit
11.BOW
"
In case where there is a bow-shaped distortion of images on the
screen.
42. Select 11.BOW with the FUNCTION UP/DOWN key.
43. Adjust BOW, and bring the vertical lines straight.
44. Press the MENU key and memorize the set value.
Straight
Straight
PARALLELOGRAM
BOW
Summary of Contents for AV29A10EUS
Page 62: ...AV29A10EUS AV29A10EUS No 51818 No 51818 2 21 2 22 PATTERN DIAGRAM MAIN PWB PATTERN FRONT ...
Page 63: ...AV29A10EUS AV29A10EUS No 51818 No 51818 2 23 2 24 POWER DEF PWB PATTERN FRONT TP E TP 91 B1 ...
Page 66: ...AV29A10EUS AV29A10EUS No 51818 No 51818 2 29 2 30 FRONT CONTROL PWB PATTERN FRONT ...