No. 51778
AV28L2EUGR
AV28L2EUBL
AV28L2EUGY
20
Item
Measuring
instrument
Test point
Adjustment part
Description
7.COLOUR
(PAL/SECAM/NTSC)
[Method of adjustment without measuring instrument]
PAL COLOUR
(PAL COLOUR)
1. Receive
PAL
broadcast.
2. Select 2.V/C from the SERVICE MENU.
3. Select 7.COLOUR with the FUNCTION UP/DOWN key.
4. Set the initial setting value for PAL COLOUR with the
FUNCTION - or + key.
5. If the colour is not the best with the initial set value, make fine
adjustment until you get the best colour.
6. Press the MENU key and memorize the set value.
SECAM COLOUR
(SECAM COLOUR)
1. Receive a SECAM broadcast.
2. Make fine adjustment of SECAM COLOUR in the same
manner as for above.
(NTSC 3.58 COLOUR)
1. Input a NTSC 3.58MHz COMPOSITE VIDEO signal from the
EXT terminal.
2. Make similar fine adjustment of NTSC 3.58 COLOUR in the
same manner as for above.
Adjustment
of SUB
COLOUR
Ⅰ
Ⅰ
Ⅰ
Ⅰ
Remote
control unit
NTSC COLOUR
(NTSC 4.43 COLOUR)
1. Receive a NTSC 4.43MHz COMPOSITE VIDEO signal from
the EXT terminal.
2. Make similar fine adjustment of 4.43 COLOUR in the same
manner as for above.
CH.
key
FUNCTION
key
(
INFORMATION
) key
i
MENU
( OK ) key