No. 51994
AV32X25EUS / AV32X250EUS
AV32X25EIGY / AV32X25EKGY
AV28X25EUS / AV28X25EIGY
AV28X25EKGY
25
Item
Measuring
instrument
Test point
Ad justment part
Description
7.COLOUR
(PAL
~
~
~
~
NT SC)
[Method of adjustment using measuring instrument]
PAL COLOUR
(PAL COLOUR)
1. Receive a PAL full field colour bar signal (75% white).
2. Select 2.V/C from the SERVICE MENU.
3. Select 7.COLOUR with the FUNCTION UP/DOWN ( / ) key.
4. Set the initial setting value of PAL COLOUR with the
FUNCTION - or + ( / ) key.
5. Connect the osc illosc ope between TP-47B and TP-E(
#
).
6. Adjust PAL COLOUR and bring the value of (
A
) in the
illustration to the values as shown giv en billow (Voltage
differenc e between white (W) and blue (B)).
7. Press the MENU key and memoriz e the s etting value.
SECAM COLOUR
(SECAM COLOUR)
1. Receive a SECAM full field colour bar signal (75% white).
2. Set the initial setting value of SECAM COLOUR with the
FUNCTION -/+ ( / ) key.
3. Adjust SECAM COLOUR and bring the value of (
A
) in the
illustration to the values as s hown given billow (Voltage
differenc e between white (W) and blue (B)).
4. Press the MENU key and memoriz e the s etting value.
(NTSC 3.58 COLOUR)
1. Input a NTSC 3.58MHz COMPOSITE VIDEO signal (full field
colour bar with 75% white) from the EXT terminal.
2. Set the initial s etting value of NTSC 3.58 COLOUR with the
FUNCTION -/+ ( / ) key.
3. Adjust NTSC 3.58 COLOUR and bring the value of (
A
) in the
illustration to the values as shown giv en billow (Voltage
differenc e between white (W) and blue (B)).
4. Press the MENU key and memoriz e the s etting value.
S UB CO LO UR
Ⅱ
Ⅱ
Ⅱ
Ⅱ
adjustment
Signal
generator
Oscilloscope
Remote
control unit
TP-47B
TP-E(
#
#
#
#
)
[CRT
SOCKET
PWB ]
NTSC COLOUR
(NTSC 4.43COLOUR)
1. When NTSC 3.58 COLOUR set, NTSC 4.43 COLOUR will
automatic ally set.
0
W
Cy
Mg
B
(A)
(-)
(+)
Y
G
R
VOLTAGE (W-B)
+
5V
VOLTAGE (W-B)
+
4V
VOLTAGE (W-B)
+
5V +6V
32” 28”