No. 51917
AV-T2922
22
Item
Measuring
instrument
Test point
Ad justment part
Description
H. POSITION
adjustment
Signal
generator
Remote
control unit
No .54 H POS.60
1. Receive a crosshatch signal. (NTSC or PAL-M)
2. Select the “No.54 H POS. 60” of the PICTURE mode in
SERVICE MENU.
3. Confirm the initial setting value of the "No.54 H POS. 60".
4. Adjust the “No.54 H POS. 60” until the screen will be
horizontally c entered.
H. POSITION
adjustment
Signal
generator
Remote
control unit
No .48 H POS.50
1. Receive a crosshatch signal. (PAL-N)
2. Select the “No.48 H POS. 50” of the PICTURE mode in
SERVICE MENU.
3. Confirm the initial setting value of the "No.48 H POS. 50".
4. Adjust the “No.48 H POS. 50” until the screen will be
horizontally c entered.
H
H"
60Hz
PAL-M or
NT SC signal
adjustment
50Hz
PAL-N signal
adjustment
ADJUSTMENT ITEM
INITIAL SETTING VALUE
No .54 H POS. 60
10
ADJUSTMENT ITEM
INITIAL SETTING VALUE
No .48 H POS. 50
06