SELF CHECK FUNCTIONS
1. Outline
This model includes protector functions for Over-current, X-ray and CRT NECK which cutoff the sub-power in the event of a malfunction and
inform of the malfunction by flashing POWER/ON TIMER LED.
The malfunction is detected according to the state of the control line input connected to the main CPU.
2. Self
check
items
Check item
Detected contents
Detection method
Abnormality state
Over-current protector
Operation
of
over-current
protection circuit
The main CPU detects at
1second intervals.
If NG is detected for more than
1ms, a malfunction is interpreted
During an abnormality the sub-
power is cutoff. The remote
controller power key operation is
not recognized and sub-power
off is maintained until the power
cord is unplugged and
reinserted.
X-ray
protector
Operation of X-ray protection
circuit
The main CPU detects at
1second intervals.
If NG is detected for more than
1ms, a malfunction is interpreted
During an abnormality the sub-
power is cutoff. The remote
controller power key operation is
not recognized and sub-power
off is maintained until the power
cord is unplugged and
reinserted.
CRT
NECK
protector
When the vertical circuit S-
correction capacitor C413 is
shorted, detect the potential
drop of the C413, and prevent
the burn damage to the CRT
NECK.
The main CPU detects at
1second intervals.
If NG is detected for more than
1ms, a malfunction is interpreted
During an abnormality the sub-
power is cutoff. The remote
controller power key operation is
not recognized and sub-power
off is maintained until the power
cord is unplugged and
reinserted.
3. Self check indicating function
The self check function begins detection about 5
seconds after power is supplied.
In the event a malfunction is detected, the sub-power is
cutoff immediately.
At this time, the POWER/ON TIMER LED flashes to
inform of the malfunction.
Item
LED flashing intervals
Priority of detection
OCP/X-ray
Red and green LED flash alternately at
0.5 second intervals
1
NECK
Red and green LED flash alternately at
1.0 second intervals
2
About 5 seconds
after
Malfuction is
detected
Detection
start
SUB-POWER OFF
Flashing
POWER /
ON TIMER LED
POWER
supplied