32
No. 52061
AV-29WS3
AV-29WX3
AV-29WH3
AV-2978TEE
Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment
of
SIDE PIN
7. EW-PIN
13. Receive a PAL cross-hatch signal.
14. Select
7. EW-PIN
with the MENU
&
/
^
key.
15. Set the initial setting value of
7. EW-PIN
with the MENU
*
/
T
key.
16. Adjust
7. EW-PIN
so that the first vertical lines at the left and right
edges on the screen are straight.
Signal
generator
Remote
control unit
Adjustment
of
TRAPEZIUM
8. EW-TRAPEZ
17. Select
8. EW-TRAPEZ
with the MENU
&
/
^
key.
18. Set the initial setting value of
8. EW-TRAPEZ
with the MENU
*
/
T
key.
19. Adjust
8. EW-TRAPEZ
so that the vertical lines at the left and right
edges on the screen are in parallel.
Signal
generator
Remote
control unit
Straight
Parallel
Adjustment
of
CORNER
Signal
generator
Remote
control unit
20. Select
9. UP CORNER
with the MENU
&
/
^
key.
21. Set the initial setting value of
9. UP CORNER
with the MENU
*
/
T
key.
22. Select
10. DW CORNER
with the MENU
&
/
^
key.
23. Set the initial setting value of
10. DW CORNER
with the MENU
*
/
T
key.
24. Adjust
9. UP CORNER
and
10. DW CORNER
so that the vertical
lines at the four corners on the screen are straight.
25. Press the DISPLAY key twice to return to the normal screen.
9. UP CORNER
10. DW CORNER