(No. YA104) 1-23
Item
Measuring
instrument
Test point
Adjustment part
Description
SUB TINT 2
adjustment
Signal
generator
Oscilloscope
Remote
control unit
[2. V/C]
7. TINT
[Method of adjustment using measuring instrument]
Notes:
•
Proceed to the following adjustment after having completed
the SUB CONTRAST adjustment.
•
Set PICTURE MODE (VSM) to “BRIGHT”.
- NTSC 3.58 TINT -
(1) Receive a NTSC 3.58 colour bar signal (full field colour
bar 75% white).
(2) Press the [COLOUR SYSTEM] key to select the NTSC
3.58 colour system.
(3) Select
2. V/C
from the SERVICE MENU.
(4) Select
7. TINT
.
(5) Set the initial setting value of NTSC 3.58.
(6) Connect the oscilloscope between TP-47G and TP-E.
(7) Adjust NTSC 3.58 TINT to set the value
(B)
in the figure to
+9V [AV-29WX14/G, AV-29WX14/S, AV-29WX24/L]
or
+13V [AV-2954W/E]
.
(8) Press the [DISPLAY] key twice to return to the normal
screen.
- NTSC 4.43 TINT -
When adjustment is done for NTSC 3.58 TINT, appropriate
values are automatically set for NTSC 4.43 TINT.
TP-47G
TP-E
[CRT
SOCKET
PWB]
M
B
(–)
0V
(+)
R
C
Y
W
(B)
G
4.7.5 AUDIO SETTING
This submenu is for display only, no adjustment is required.
Function
Item
Setting value
AUDIO
1. DC XO ADJ
FOH
2. NICAM LOWER ERR LIM
6FH
3. NICAM UPPER ERR LIM
BOH
4. A2 ID THR
00H
Function
Item
100Hz
300Hz
1kHz
3kHz
8kHz
MENU EQUALIZER
DYNAMIC
+4
+3
-10
+3
+4
MUSIC
+7
+2
+5
+2
+7
NEWS
-6
+1
+6
+1
-6
USER
0
0
0
0
0