AV-29LS
AV-29LX
AV-29LH
AV-2908TEE
No. 51839
29
Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment
of
VER. SCURVE
4. VER. SCURVE
26. Select
4. VER. SCURVE
with the MENU
&
/
^
key.
27.Set the initial setting value of
4. VER. SCURVE
with the MENU –/+
key.
28. Adjust
4. VER. SCURVE
so that the spaces of each line on TOP,
CENTER and BOTTOM become uniform.
Signal
generator
Remote
control unit
TOP
CENTER
BOTTOM
Adjustment
of
UP CORNER
and
DW CORNER
9. UP CORNER
10. DW CORNER
29. Select
9. UP CORNER
with the MENU
&
/
^
key.
30. Set the initial setting value of
9. UP CORNER
with the MENU –/+
key.
31. Sekect
10. DW CORNER
with the MENU
&
/
^
key.
32. Set the initial setting value of
10. DW CORNER
with the MENU –/+
key.
33. Adjust
9. UP CORNER
and
10. DW CORNER
so that the vertical
lines at the four corners on the screen are straight.
Signal
generator
Remote
control unit
Adjustment
of
HOR. PARALL
11. HOR. PARALL
34. Select
11. HOR. PARALL
with the menu
&
/
^
key.
35. Set the initial setting value of
11. HOR. PARALL
with the menu –/+
key.
36. Adjust
11. HOR. PARALL
to optimize the parallelogram distortion.
Signal
generator
Remote
control unit
Adjustment
of
HOR. BOW
12. HOR. BOW
37. Select
12. HOR. BOW
with the menu
&
/
^
key.
38. Set the initial setting value of Select
12. HOR. BOW
with the menu
–/+ key.
39. Adjust
12. HOR. BOW
to optimize the horizontal arc distortion.
40. Press the DISPLAY key twice to return to the normal screen.
Signal
generator
Remote
control unit
Straight