No. 51754
AV-29RF6
27
Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment
of
V-SHIFT
Signal
generator
Remote
control unit
1. V- SHIFT
●
At first, select the ASPECT mode to REGULAR.
1. Input the circle pattern signal.
2. Select 4.DEF from the SERVICE MENU.
3. Select 1.V-SHIFT with the MENU UP/DOWN key.
4. Adjust V-SHIFT to make
A = B
.
5. Press the OK key and memorize the set value.
Adjustment
of V-SIZE
Signal
generator
Remote
control unit
2.V-SIZE
6. Input the cross-hatch signal.
7. Select 2.V-SIZE and set the initial setting value.
8. Adjust V-SIZE and make sure that the vertical screen size is in
the bellow table.
9. Press the OK key and memorize the set value.
A
B
[VERTICAL SIZE]
ASPECT MODE
REGULAR
ZOOM
16 : 9
V SIZE
92%
74%
295mm
(90% position)
Screen size
Screen
size
Picture
size
100%
Picture size 100%
Summary of Contents for AV-28WFR1EK/A
Page 39: ...AV 29RF6 AV 29RF6 No 51754 No 51754 3 2 5 2 6 CIRCUIT DIAGRAMS MAIN PWB CIRCUIT DIAGRAM ...
Page 40: ...AV 29RF6 AV 29RF6 No 51754 No 51754 4 2 7 2 8 ...
Page 41: ...AV 29RF6 AV 29RF6 No 51754 No 51754 5 54 1 2 9 2 10 POWER DEF PWB CIRCUIT DIAGRAM ...
Page 42: ...AV 29RF6 AV 29RF6 No 51754 No 51754 6 105 5 2 11 2 12 CRT SOCKET PWB CIRCUIT DIAGRAM ...
Page 43: ...AV 29RF6 AV 29RF6 No 51754 No 51754 7 103 7 2 13 2 14 FRONT CONTROL PWB CIRCUIT DIAGRAM ...
Page 44: ...AV 29RF6 AV 29RF6 No 51754 No 51754 8 2 15 2 16 AV SEL PWB CIRCUIT DIAGRAM ...
Page 45: ...AV 29RF6 AV 29RF6 No 51754 No 51754 9 FRONT 2 17 2 18 PATTERN DIAGRAMS MAIN PWB PATTERN ...
Page 46: ...AV 29RF6 AV 29RF6 No 51754 No 51754 10 FRONT TP E TP 91 B1 2 19 2 20 POWER DEF PWB PATTERN ...
Page 47: ...AV 29RF6 AV 29RF6 No 51754 No 51754 11 TOP 2 21 2 22 CRT SOCKET PWB PATTERN ...
Page 48: ...AV 29RF6 AV 29RF6 No 51754 No 51754 12 FRONT FRONT 2 23 2 24 FRONT CONTROL PWB PATTERN ...
Page 49: ...AV 29RF6 AV 29RF6 No 51754 No 51754 13 TOP 29RF6 HSAE VP0007 DP6053 2 25 AV SEL PWB PATTERN ...