(No.52139)1-13
4.6
ADJUSTMENT PROCEDURE
4.6.1 FOCUS / SCREEN ADJUSTMENT
4.6.2 AGC ADJUSTMENT
Item
Measuring
instrument
Test point
Adjustment part
Description
FOCUS
adjustment
Signal
generator
Remote
control unit
FOCUS VR
[On the FBT]
(1) Receive a cross-hatch signal.
(2) Adjust FOCUS VR on the FBT as thin as possible.
SCREEN
adjustment
Signal
generator
Remote
control unit
1pin (GND)
RGB cathodes
[CRT PWB]
SCREEN VR
[On the FBT]
(1) Receive a colour-bar signal.
(2) Ground pin of probe will be connected to 1pin (GND)
of the CRT socket.
(3) 1/100 oscilloscope probe to RGB cathodes on CRT
PWB.
(4) Adjust all control functions (brightness, colour and
contrast) to minimum settings.
(5) Adjust the SCREEN VR until acthode voltage
becomes 150V.
Item
Measuring
instrument
Test point
Adjustment part
Description
AGC
adjustment
Signal
generator
Remote
control unit
Volt meter
AGC
(1) Receive a PAL BG signal at 60dBmV RF signal
level.
(2) Enter the SERVICE MENU.
(3) Press the [GREEN] key, then enter the VIDEO
adjustment group.
(4) Select AGC.
(5) Adjust AGC by pressing till voltage at pin 1 of
TUNER is equal to 3.0V.
(6) Press the [INFORMATION] key and memorize the
set value.
FBT
FOCUS VR
SCREEN VR
FBT
FOCUS VR
SCREEN VR